Stovax Coal Effect Stove Range Conventional Flue manual Replacing Parts, Burner Unit Removal

Page 17

SERVICING INSTRUCTIONS

REPLACING PARTS

1.GENERAL

1.1All principal components can be replaced without removing the stove from its installation, although it will be necessary to remove the door and ceramic outer casing in order to access most components. In order to remove the casing, use the following procedure:

1.2Remove the door retaining nuts using the tool provided and place the door to one side.

1.3Carefully remove the top blanking plate and grille and place to one side, gently remove the top ceramic panel, see diagram 1. If the unit has been connected to a top exit flue, it will be necessary to lift and support the grille and top ceramic panel whilst removing the outer ceramic components.

1

1.4Gently lift the front ceramic panel, and pull away from the sub-frame to clear the retaining bolts, see diagram 2.

2

1.5Carefully remove the two side panels by lifting, and gently pulling clear of the retaining bolts, see diagram 3. It may not be necessary to remove both of the side panels.

This should allow full access to all major components.

3

2.BURNER UNIT REMOVAL

2.1Turn the gas supply off at the isolation device. Ensure the unit is cool.

Use cover material to front of appliance to protect paintwork etc.

Remove the door and place to one side. (4 nuts).

Carefully remove the ceramic fuel components to a safe place.

Remove front cover-plate (2 screws).

Remove cover plate fixing bracket (2 wing nuts).

(Small Stoves only)

Unscrew pilot union nut on gas valve. See diagram 4.

4

Viewing slot on Marlborough only

AR0391

2.2Disconnect thermocouple from gas valve. See diagram 2. Remove ignition lead from electrode. (Cut cable tie to ignition lead if required).

17

Image 17
Contents Ceramica Coal Effect Stove Range Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail Lighting the Appliance User InstructionsGeneral Turning the Stove OFF Cleaning the FireUpgrading Your Stove Fuel BED ArrangementMedium Ceramica Gazco Flue Sure System Installation DetailsFlame Failure Device RunningTechnical Specification Installation InstructionsSite Requirements Installation of the GAS SupplyFlue and Chimney Requirements Appliance LocationControl Upgrade InstallationSafety Precautions Installation of the StoveInstallation Instructions Medium Ceramica Lighting Commissioning CommissioningServicing Instructions Servicing / Fault Finding ChartsFlame Failure Functional Check Fault Finding ChartsIgnition Functional Check Burner Unit Removal Replacing PartsPilot Unit GAS Valve Ignition Lead and PiezoPiezo Main Injector Magnetic Safety ValvePrimary Aeration Plate Short Spares List Changing Between GAS TypesService Records Member of the Stovax Group