Stovax Coal Effect Stove Range Conventional Flue manual Installation Instructions

Page 11

INSTALLATION INSTRUCTIONS

INSTALLATION

3.5Remove the assembly and drill the two holes using a No. 12 masonry bit. Push the rawl plugs into the holes, and place the engine assembly in position, secure to the floor using the screws provided. See diagram 3.

3

158mm

AR0359

3.6Having run the gas supply to the stove, PURGE THE SUPPLY PIPE, this is essential to expel any debris that may block the gas controls. connect the gas supply to the 8mm- compression elbow at the RH rear corner of the stove, ensuring that the pipe position does not interfere with the location of the outer steel casing. See diagram 4.

4

3.7Open the second carton, and carefully remove the ceramic outer casing components. Gently position the LH side so that the bolt heads on the engine subframe locate in the keyhole slots on the back of the panel, and gently slide into place so that the ceramic comes to rest on the floor. Repeat

5

the procedure for the RH side, see diagram 5.

3.8Remove the cast iron door using the tool provided, and carefully place to one side. Gently position the front ceramic panel so that the side panels locate inside the returns on the front panel, engage the bolt heads in the brackets on the back of the panel and gently slide into place so that the ceramic comes to rest on the floor, ensure that the opening in the panel sits centrally around the fire box opening, see diagram 6.

6

11

Image 11
Contents Ceramica Coal Effect Stove Range Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail Lighting the Appliance User InstructionsGeneral Fuel BED Arrangement Cleaning the FireTurning the Stove OFF Upgrading Your StoveMedium Ceramica Running Installation DetailsGazco Flue Sure System Flame Failure DeviceTechnical Specification Installation InstructionsAppliance Location Installation of the GAS SupplySite Requirements Flue and Chimney RequirementsInstallation of the Stove InstallationControl Upgrade Safety PrecautionsInstallation Instructions Medium Ceramica Lighting Commissioning CommissioningServicing Instructions Servicing / Fault Finding ChartsFlame Failure Functional Check Fault Finding ChartsIgnition Functional Check Burner Unit Removal Replacing PartsPilot Unit GAS Valve Ignition Lead and PiezoPiezo Main Injector Magnetic Safety ValvePrimary Aeration Plate Short Spares List Changing Between GAS TypesService Records Member of the Stovax Group