SERVICING INSTRUCTIONS
REPLACING PARTS
4.IGNITION LEAD AND PIEZO
4.1Gain access to the back of the pilot assembly, (see section
2)and disconnect the ignition lead from the electrode.
4.2Remove the front cover from the control valve, (see diagrams 10 and 11). Disconnect the other end of the ignition lead from the valve body. Note the existing route of the ignition lead.
10
AR0915
11
AR0916
4.3Replace with a new ignition lead following the same route as the old one. Replace the valve cover and the pilot assembly.
4.4Check operation of the new ignition lead.
5.PIEZO
5.1The piezo assembly used on this appliance is not serviceable and is unlikely to fail.
5.2If a new piezo is required it will be necessary to change the gas valve. Refer to Section 6.
6.GAS VALVE
6.1Turn the gas supply off at the isolation device.
6.2Disconnect the 2x8mm and 1x4mm gas pipe fittings at the back of the gas valve and also disconnect the thermocouple, see diagram 12.
12
6.3Undo the single screw that secures the
13
AR0915
6.4To release the
14
AR0916
19