Stovax Coal Effect Stove Range Conventional Flue Appliance Commissioning Checklist, GAS Check

Page 3

APPLIANCE COMMISSIONING CHECKLIST

IMPORTANT NOTICE

Explain the operation of the appliance to the end user, hand the completed instructions to them for safe keeping,

as the information will be required when making any guaranteed claims.

FLUE CHECK

 

PASS

FAIL

 

 

 

 

 

1.

Flue is correct for appliance

 

 

 

 

 

 

 

 

2.

Flue flow test

 

 

 

 

 

 

 

 

3.

Spillage test

 

 

 

 

 

 

 

GAS CHECK

 

 

 

1.

Gas soundness & let by test (Please circle Y / N as appropriate)

 

Y / N

Y / N

 

 

 

 

 

2.

Standing pressure test in figures (e.g. 20 mb)

 

 

mb

 

 

 

 

 

3.

Appliance working pressure (on High Setting) in figures (e.g. 20 mb)

 

 

mb

 

NB All other gas appliances must be operating on full

 

 

 

4.

Gas rate

 

m3/h

 

 

 

 

 

 

5.

Does ventilation meet appliance requirements

 

 

 

 

 

 

 

 

6.

Have controls been upgraded (Upgradeable models only)

8455 Standard

YES

NO

 

 

 

 

 

8456 Programmable Time & Temperature

YES

NO

DEALER AND INSTALLER INFORMATION

Dealer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date of Purchase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Serial No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gas Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation Company. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Engineer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Corgi Reg No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date of Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and your

local Gazco dealer. This guarantee will be invalid, to the extent permitted by law, if the above Appliance Commissioning Checklist is

not fully completed by the installer and available for inspection by a Gazco engineer. The guarantee will only be valid during the second year, to the extent permitted by law, if the annual service recommended in the Instructions for Use has been completed by a Corgi registered engineer, and a copy of the service visit report is available for inspection by a Gazco engineer.

3

Image 3
Contents Ceramica Coal Effect Stove Range Contents Appliance Commissioning Checklist Flue Check Pass FailGAS Check User Instructions GeneralLighting the Appliance Fuel BED Arrangement Cleaning the FireTurning the Stove OFF Upgrading Your StoveMedium Ceramica Running Installation DetailsGazco Flue Sure System Flame Failure DeviceTechnical Specification Installation InstructionsAppliance Location Installation of the GAS SupplySite Requirements Flue and Chimney RequirementsInstallation of the Stove InstallationControl Upgrade Safety PrecautionsInstallation Instructions Medium Ceramica Lighting Commissioning CommissioningServicing Instructions Servicing / Fault Finding ChartsFault Finding Charts Ignition Functional CheckFlame Failure Functional Check Burner Unit Removal Replacing PartsPilot Unit Ignition Lead and Piezo PiezoGAS Valve Magnetic Safety Valve Primary Aeration PlateMain Injector Short Spares List Changing Between GAS TypesService Records Member of the Stovax Group