| SERVICING INSTRUCTIONS | |||
| REPLACING PARTS | |||
6.5 | Disconnect the ignition lead from the gas valve. | 8.2 Rotate the injector until it is fully removed, and install the | ||
6.6 | Undo the two bolts securing the gas valve to the appliance | correct replacement injector. Reassemble and turn the gas | ||
supply on, check for leaks. | ||||
| and remove the valve. | |||
|
|
| ||
6.7 | Replace in reverse order. |
| 9. GAZCO FLUE SURE SYSTEM | |
6.8 | Check all joints for gas leaks. Check operation of the |
| ||
. |
| |||
| thermocouple and ignition lead. |
| ||
7.1 | Turn the gas supply off at the isolation device. Undo the | If the stove has been installed in a restrictive location, it | ||
|
| may be necessary to remove the stove from its location. | ||
| 7. MAGNETIC SAFETY VALVE | 9.1 Locate the sensor in the draught diverter opening, and | ||
| gently pull the two wires off the terminals. Undo the two | |||
| thermocouple connection from the back of the gas valve. | |||
| taptite screws and remove the sensor and the two plastic | |||
| Pull the sensor leads clear and remove the interrupter | spacers. See diagram 14. | ||
| block. |
|
| |
7.2 | Undo the magnetic | 14 |
| |
| control valve. Gently tap out the magnetic valve and replace |
|
| |
| with a new unit. Replace the retaining nut and tighten. See |
|
| |
| diagram 12. |
|
|
7.3Reassemble the interrupter block and leads. Secure the thermocouple connection in the rear of the gas control. (Do not overtighten). Turn the gas supply on and check the entire pipework and valve joints for any leaks.
12
| 9.2 | Refit a new sensor ensuring the spacers are located between | ||
|
|
| the sensor and the bracket. Replace the two leads. | |
| 9.3 | If it has been necessary to remove the stove, ensure that all | ||
|
|
| disturbed gas joints are checked for gas soundness when | |
|
|
| reinstalled, and repeat the flue clearance test as detailed in | |
|
|
| the Commissioning Section. | |
|
|
|
| 10. PRIMARY AERATION PLATE |
| 10.1 | Turn the gas supply off at the isolation device. | ||
| ||||
8. MAIN INJECTOR | 10.2 | Locate the aeration plate on the underside of the airbox | ||
|
| and remove the Nyloc nut, see diagram 15. | ||
8.1 Turn the gas supply off at the isolation device. Locate the |
|
|
|
|
main injector on the LH side of the airbox, undo the |
| 15 |
| |
compression nut and pull the pipe clear of the injector |
|
| ||
|
| |||
body, see diagram 13, A. |
|
|
|
|
13 |
|
A |
|
| AR0381 |
| 10.3 Remove the plate and replace with the correct size, ensure |
| that the hole(s) in the plate align correctly with the holes in |
AR0389 | the underside of the airbox and replace the Nyloc nut. |
20