Stovax Coal Effect Stove Range Conventional Flue manual Pilot Unit

Page 18

SERVICING INSTRUCTIONS

REPLACING PARTS

5

A AR0943

2.3Loosen main injector nut on airbox and disconnect from injector, see diagram 6, A.

6

A

AR0498

2.4Remove the 2 screws attaching burner to back of unit, see diagrams 7. Carefully withdraw burner unit upwards and tilt to remove the burner through door opening. Remove the 2 screws holding the heat shield in place.

7

3.PILOT UNIT

3.1Remove the burner module as described in Servicing Section 2 above. Carefully cut the cable ties holding the thermocouple to the pilot pipe. Remove the HT lead from the electrode, undo the two retaining screws and remove the pilot. See diagram 8.

8

3.2When replacing the pilot ensure the thermocouple follows its original route, i.e. along the pilot pipe. Attach the thermocouple to the pipe with new cable ties.

7 7

9

AR0385

Replace in reverse order checking all joints for leaks.

3.3Set the spark gap. See diagram 9.

18

Image 18
Contents Ceramica Coal Effect Stove Range Contents Appliance Commissioning Checklist Flue Check Pass FailGAS Check User Instructions GeneralLighting the Appliance Upgrading Your Stove Cleaning the FireTurning the Stove OFF Fuel BED ArrangementMedium Ceramica Flame Failure Device Installation DetailsGazco Flue Sure System RunningInstallation Instructions Technical SpecificationFlue and Chimney Requirements Installation of the GAS SupplySite Requirements Appliance LocationSafety Precautions InstallationControl Upgrade Installation of the StoveInstallation Instructions Medium Ceramica Lighting Commissioning CommissioningServicing / Fault Finding Charts Servicing InstructionsFault Finding Charts Ignition Functional CheckFlame Failure Functional Check Replacing Parts Burner Unit RemovalPilot Unit Ignition Lead and Piezo PiezoGAS Valve Magnetic Safety Valve Primary Aeration PlateMain Injector Changing Between GAS Types Short Spares ListService Records Member of the Stovax Group