Stovax F40 manual Safety Precautions, Installation of the Stove

Page 11

INSTALLATION INSTRUCTIONS

INSTALLATION

ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE. REFER TO THE DATABADGE AND TECHNICAL SPECIFICATIONS ON PAGE 9

FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 11 OF THE SERVICING INSTRUCTIONS.

1.SAFETY PRECAUTIONS

1.1This appliance must be installed in accordance with the rules in force, and used only in a sufficiently ventilated space. Please read these instructions before installation and use of this appliance.

1.2These instructions must be left intact with the user.

1.3Do not attempt to burn rubbish on this appliance.

1.4In your own interest, and those of safety, this appliance must be installed by competent persons in accordance with local and national codes of practice. Failure to install the appliance correctly could lead to prosecution.

2.INSTALLATION OF THE STOVE

2.1Remove the appliance from its packaging. It will now be necessary to decide upon top or rear flue exit, the stove is factory built for rear exit but is easily converted by swapping the flue spigot with the blanking plate and putting the blanking plate on the rear of the stove.

2.2Open the lower door by pressing until a “click” is heard, and gently lowering down.

2.3Remove the glass frame by undoing the six pozidrive screws. The four black screws are for removing the entire firebox if required. Remove the ceramic components and place carefully to one side. Remove the lower cover panel by undoing the two pozidrive screws. See diagram 1.

1

AR1454

2.3Disconnect the lead for the touchpad and the two leads for the TTB See Diagram 2.

2

AR1463

2.4Undo the two screws at the back of the firebox and gently pull the burner unit forward. See diagram 3.

3

AR1457

2.5At the rear of the burner unit, undo the thermocouple and disconnect the TTB leads. Now remove the burner unit completely. See diagram 4.

4

AR1462

11

Image 11
Contents F40 Avanti Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail General User InstructionsLow battery display Hand Set Ensure the Appliance is Cold Before Proceeding Cleaning the F40 AvantiAdvice on Handling and Disposal of Fire Ceramics Gazco Flue Sure System Fuel BED Arrangement‘RUNNING IN’ Installation DetailsBattery Replacement Flame Failure DevicePacking Checklist Installation InstructionsTechnical Specification Appliance Location Installation of the GAS SuppySite Requirements Flue and Chimney RequirementsInstallation of the Stove InstallationSafety Precautions AR1470 Door Replacement Programming the Handset Servicing InstructionsCommissioning CommissioningIgnition Functional Servicing ChartCheck Servicing RequirementsFlame Failure Functional Check Fault Finding ChartsIgnition Functional Check Pilot Unit Replacing PartsMain Burner Aeration Plate Magnetic Safety ValveIgnition Lead Control Unit Main InjectorGAS Valve Changing Between GAS Types Butane Spare Parts ListLPG Service Records Page Member of the Stovax Group