Stovax F40 manual Servicing Chart, Check, Servicing Requirements, Ignition Functional

Page 15

SERVICING INSTRUCTIONS

SERVICING CHART

CHECK 1

LIGHT

around the pilot assembly, the spark, clean the area.

Yes

Does the pilot light?

No

Is the control being operated correctly?

Yes

Will the pilot light with a match?

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gas turned on to the appliance?

 

Yes

gas pressure correct?

 

 

 

Is the

 

 

Is the

 

 

 

 

 

Yes

Has the system got any air in it?

 

 

No

point,

 

check the inlet test and pilot filter.

SYSTEM OK

IGNITION FUNCTIONAL

PILOT WILL NOT

Ensure there is no debris (e.g. soot, etc.) which could short

Yes

No

the valve.

a spark?

 

 

 

Section retry.

Operate

Is there

 

Consult 2 and

 

 

 

 

Yes

Check alignment of pilot burner head, change the ignition lead, see diagram 1 on page 17.

No

 

No

 

 

 

Check isolation tap and gas meter, retry.

 

 

 

Correct and retry.

 

 

 

Yes

Purge the gas pipes and retry.

in the system, seating, valve

blockage the mag

There is a

SEE 'NO SPARK' CHART

No

1. SERVICING REQUIREMENTS

This appliance must be serviced at least once a year by a competent person.

All tests must be serviced by best practice as described by the current CORGI recommendations.

1.1Before any test are undertaken on the appliance, conduct a gas soundness test for the property to ensure that there are no gas leaks prior to starting work.

1.2Before any tests are undertaken on the applaince it is also recommended to fully check the operation of the appliance.

1.3Special checks

1.3.1Clean any lint or fluff from the pilot - pay particular attention to the aeration hole in the side of the pilot

1.3.2Clean away any fluff or lint from under the burner

1.3.3Check that the spark gap on the pilot is correct

1.4Correct any faults found during the initial tests and then re- commission the appliance conducting the usual safety checks.

1.5Advise the customer of any remedial action taken.

15

Image 15
Contents F40 Avanti Contents Appliance Commissioning Checklist Flue Check Pass FailGAS Check General User InstructionsLow battery display Hand Set Cleaning the F40 Avanti Advice on Handling and Disposal of Fire CeramicsEnsure the Appliance is Cold Before Proceeding Gazco Flue Sure System Fuel BED Arrangement‘RUNNING IN’ Installation DetailsBattery Replacement Flame Failure DeviceInstallation Instructions Technical SpecificationPacking Checklist Appliance Location Installation of the GAS SuppySite Requirements Flue and Chimney RequirementsInstallation Safety PrecautionsInstallation of the Stove AR1470 Door Replacement Programming the Handset Servicing InstructionsCommissioning CommissioningIgnition Functional Servicing ChartCheck Servicing RequirementsFault Finding Charts Ignition Functional CheckFlame Failure Functional Check Replacing Parts Main BurnerPilot Unit Magnetic Safety Valve Ignition LeadAeration Plate Main Injector GAS ValveControl Unit Changing Between GAS Types Spare Parts List LPGButane Service Records Page Member of the Stovax Group