SERVICING INSTRUCTIONS

REPLACING PARTS

1.GENERAL

1.1All principle components can be replaced without removing the appliance from its installation, although it is essential that the gas supply to the appliance is turned off at the isolation device before proceeding further.

1.2ENSURE THAT THE APPLIANCE IS COLD BEFORE COMENCING WORK ON IT.

1.3Remove the batteries from the battery box.

1.4If access to the components is restricted the burner and control system is a self contained unit and can be removed as a single unit for easy maintenance.

2.MAIN BURNER

2.1Remove the door from the stove, open the lower door, and remove the lower panel. Remove the batteries from the battery box, undo the six pozidriv screws and remove the glass frame. See diagram 1

1

AR1454

2.2Carefully remove the ceramic components from the stove and store safely. Remove the touchpad panel

2.3Disconnect the TTB and the touchpad leads from the control unit. See diagram 2

2

AR1463

2.4Undo the gas connection at the pressure test point, and undo the two screws at the back of the firebox. See diagram 3

3

AR1457

2.5Carefully pull the burner unit forward until access to the rear of the valve is possible. Undo the thermocouple lead and remove the TTB wires. See diagram 4

4

AR1462

2.5The burner unit can now be removed to work on.

2.6Reassemble in the reverse order, check for gas leaks. When connecting the TTB wires in the back of the valve, it is essential for the wire with the red highlight be closest the valve. Note also, that the connectors for the TTB in the control unit are different sizes.

3.PILOT UNIT

3.1Follow the steps 2.1 to 2.5 above, making sure that the gas supply is isolated at the isolation point.

3.2With the burner unit removed, undo the two screws and remove the front aeration guide. See diagram 5

5

AR1443

17

Image 17
Contents F40 Avanti Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail General User InstructionsLow battery display Hand Set Ensure the Appliance is Cold Before Proceeding Cleaning the F40 AvantiAdvice on Handling and Disposal of Fire Ceramics Gazco Flue Sure System Fuel BED ArrangementBattery Replacement Installation DetailsFlame Failure Device ‘RUNNING IN’Packing Checklist Installation InstructionsTechnical Specification Site Requirements Installation of the GAS SuppyFlue and Chimney Requirements Appliance LocationInstallation of the Stove InstallationSafety Precautions AR1470 Door Replacement Commissioning Servicing InstructionsCommissioning Programming the HandsetCheck Servicing ChartServicing Requirements Ignition FunctionalFlame Failure Functional Check Fault Finding ChartsIgnition Functional Check Pilot Unit Replacing PartsMain Burner Aeration Plate Magnetic Safety ValveIgnition Lead Control Unit Main InjectorGAS Valve Changing Between GAS Types Butane Spare Parts ListLPG Service Records Page Member of the Stovax Group