Stovax F40 manual Fuel BED Arrangement, Door Replacement

Page 13

INSTALLATION INSTRUCTIONS

INSTALLATION

IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY REQUIRE ATTENTION - SEEK EXPERT ADVICE.

2.15The flue system may now be connected to the stove, ensure that all joints are sealed with a suitable fire resistant sealant. It is also recommended that a physical retention method be used at the flue spigot joint, self-tapping screws being favoured.

2.16Connect a suitable pressure gauge to the test point located on the inlet fitting, and turn the gas supply on. Light the stove and check all gas joints for gas soundness. Turn the stove to maximum and check that the supply pressure is as stated on the data badge. Turn the gas off and replace the test point screw, turn the gas on and check the test point for gas soundness.

3.FUEL BED ARRANGEMENT

3.1Place the flame baffle onto the burner and push against the rear tray lip. See diagram 11.

11

AR0359

3.2Locate the rear panel against the spacer brackets and slide down so that it locates on the ledge of the flame baffle. See diagram 12.

12

AR0360

3.3Locate the front coal between the heat shield and the flame baffle so its ends sit flat on the burner skin. See diagram 13.

13

AR0361

3.4Place five of the loose round coals on the front coal so they lean against the flame baffle, in between the fingers. Place the two rectangular coals against the reflector panels, one either side, behind the front row of loose coals. See diagram 14.

14

AR0362

3.5Place four of the loose round coals behind the first row so that they sit on the fingers, the two outer ones should touch the rectangular coals. See diagram 15.

15

AR0363

3.6Place the three remaining coals behind the centre row so that they touch the back panel. See diagram 16.

16

AR0364

4.DOOR REPLACEMENT

4.1After laying out the coals, replace the glass panel. Tighten the six pozidrive screws, working from the top down. Do not over tighten. Lower the front door on by holding at 90 degrees to the appliance and lowering down on to the two hinge pins. See diagram 17.

17

AR1363

13

Image 13
Contents F40 Avanti Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check General User InstructionsLow battery display Hand Set Advice on Handling and Disposal of Fire Ceramics Cleaning the F40 AvantiEnsure the Appliance is Cold Before Proceeding Gazco Flue Sure System Fuel BED ArrangementBattery Replacement Installation DetailsFlame Failure Device ‘RUNNING IN’Technical Specification Installation InstructionsPacking Checklist Site Requirements Installation of the GAS SuppyFlue and Chimney Requirements Appliance LocationSafety Precautions InstallationInstallation of the Stove AR1470 Door Replacement Commissioning Servicing InstructionsCommissioning Programming the HandsetCheck Servicing ChartServicing Requirements Ignition FunctionalIgnition Functional Check Fault Finding ChartsFlame Failure Functional Check Main Burner Replacing PartsPilot Unit Ignition Lead Magnetic Safety ValveAeration Plate GAS Valve Main InjectorControl Unit Changing Between GAS Types LPG Spare Parts ListButane Service Records Page Member of the Stovax Group