2.10 To turn the F40 Avanti off (Touch Pad)

2.10.1Press the ON / OFF button (A) once and the F40 Avanti will turn off. See diagram 4.

4

C

B

A

 

AR1455

3. CLEANING THE F40 AVANTI

ENSURE THE APPLIANCE IS COLD BEFORE PROCEEDING.

3.1The outside casing of the F40 Avanti should be cleaned using a damp cloth.

3.2To clean the glass frame, remove the front as detailed in the installation instructions.

3.3Remove the glass frame by unscrewing the six pozidrive screws. See diagram 5.

5

AR1454

3.4To clean the glass surface, Gazco recommends you use a ceramic glass product generally sold for cleaning ceramic hobs.

3.5Ensure that the fibreglass seal on the glass frame is intact. Replace the six screws working from the top down. Tighten the screws evenly.

NEVER OPERATE THE APPLIANCE WHEN THE GLASS PANEL IS REMOVED OR BROKEN.

ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS

The fuel effect and side panels in this appliance are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application.

Protective clothing is not required when handling these articles, but we recommend you follow normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking.

To ensure that the release of RCF fibres are kept to a minimum, during installation and servicing a HEPA filtered vacuum is recommended to remove any dust accumulated in and around the appliance before and after working on it. When servicing the appliance it is recommended that the replaced items are not broken up, but are sealed within heavy duty polythene bags and labelled as RCF waste.

RCF waste is classed as stable, non-reactive hazardous waste and may be disposed of at a licensed landfill site.

Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; wash hands thoroughly after handling the material.

6

Image 6
Contents F40 Avanti Contents Appliance Commissioning Checklist Flue Check Pass FailGAS Check User Instructions GeneralLow battery display Hand Set Cleaning the F40 Avanti Advice on Handling and Disposal of Fire CeramicsEnsure the Appliance is Cold Before Proceeding Fuel BED Arrangement Gazco Flue Sure SystemFlame Failure Device Installation DetailsBattery Replacement ‘RUNNING IN’Installation Instructions Technical SpecificationPacking Checklist Flue and Chimney Requirements Installation of the GAS SuppySite Requirements Appliance LocationInstallation Safety PrecautionsInstallation of the Stove AR1470 Door Replacement Commissioning Servicing InstructionsCommissioning Programming the HandsetServicing Requirements Servicing ChartCheck Ignition FunctionalFault Finding Charts Ignition Functional CheckFlame Failure Functional Check Replacing Parts Main BurnerPilot Unit Magnetic Safety Valve Ignition LeadAeration Plate Main Injector GAS ValveControl Unit Changing Between GAS Types Spare Parts List LPGButane Service Records Page Member of the Stovax Group