Stovax F40 manual Gazco Flue Sure System, Changing Between GAS Types

Page 20

SERVICING INSTRUCTIONS

REPLACING PARTS

10.GAZCO FLUE SURE SYSTEM

10.1Open and remove the front door. Remove the glass frame. Carefully remove the ceramic components and place to one side. Undo the two screws at the back of the firebox and carefully withdraw the bracket. See diagram 16

16

AR1442

10.2Disconnect the two sender wires. Undo the two taptite screws and remove the sensor and the two plastic spacers. See diagram 17

17

AR1446

10.3Refit the new sensor ensuring that the plastic spacers are between the sensor and the bracket. Refit the leads. See diagram 18

18

AR1452

10.4Feed the cable back through the hole as you replace the bracket. When the bracket is located correctly it will sit flush with the back panel without force required. If not positioned correctly the bracket will sit at an angle. See diagram 19

19

AR1447

AR1448

11. CHANGING BETWEEN GAS TYPES

In order to change between gas types, it will be necessary to change the following items

Pilot Unit

Control Valve**

Main Injector

Aeration Plate

Control Unit

Data Badge

The relevant parts can be ordered from Gazco, always quote the appliance type and serial number when ordering spare parts.

**NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR CORRECT GAS TYPE AND MODEL, A NEW UNIT WILL NEED TO BE ORDERED WHEN CHANGING BETWEEN GAS TYPES.

20

Image 20
Contents F40 Avanti Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail User Instructions GeneralLow battery display Hand Set Ensure the Appliance is Cold Before Proceeding Cleaning the F40 AvantiAdvice on Handling and Disposal of Fire Ceramics Fuel BED Arrangement Gazco Flue Sure SystemInstallation Details Battery ReplacementFlame Failure Device ‘RUNNING IN’Packing Checklist Installation InstructionsTechnical Specification Installation of the GAS Suppy Site RequirementsFlue and Chimney Requirements Appliance LocationInstallation of the Stove InstallationSafety Precautions AR1470 Door Replacement Servicing Instructions CommissioningCommissioning Programming the HandsetServicing Chart CheckServicing Requirements Ignition FunctionalFlame Failure Functional Check Fault Finding ChartsIgnition Functional Check Pilot Unit Replacing PartsMain Burner Aeration Plate Magnetic Safety ValveIgnition Lead Control Unit Main InjectorGAS Valve Changing Between GAS Types Butane Spare Parts ListLPG Service Records Page Member of the Stovax Group