Stovax Ceramica Manhattan Wood Stove manual Piezo, GAS Valve, Magnetic Safety Valve, Main Injector

Page 24

SERVICING INSTRUCTIONS

REPLACING PARTS

4.3To release the right hand side of the control cover insert the narrow blade screwdriver into the slot shown in diagram 9. Lever it gently and pull from the right hand side at the same time. The cover will now come off, there is a small cylindrical metal spacer inside the cover, this must be kept and replaced on the fixing screw during reassembly.

9

AR0916

4.4Disconnect the end of the ignition lead from the valve body, see diagram 10, Arrow B, note the existing route of the ignition lead.

10

B

AR0943

4.5Replace with a new ignition lead following the same route as the old one. Replace the valve cover and the pilot assembly.

4.6Check the operation of the new ignition lead.

5.PIEZO

5.1The piezo assembly used on this appliance is not serviceable and is unlikely to fail.

6.GAS VALVE

6.1Turn the gas supply off at the isolation device.

6.2Disconnect the 2 x 8mm and 1 x 4mm gas pipe fittings at the back of the gas valve and also disconnect the thermocouple, see Diagram 11, Arrow A.

6.3Remove the control valve cover and disconnect the ignition lead from the gas valve, see section 4.

6.4Undo the two bolts securing the gas valve to the appliance and remove the valve, see diagram 11, Arrow C

6.5Replace in reverse order.

6.6Check all joints for gas leaks, check the operation of the thermocouple and ignition lead.

11B

C

C

A AR0943

7.MAGNETIC SAFETY VALVE

7.1Turn the gas supply off at the isolation device. Undo the thermocouple connection from the back of the gas valve.

7.2Undo the mag valve retaining nut at the back of the control valve, gently tap out the mag valve and replace with a new unit. Replace the retaining nut and tighten. See diagram 11, Arrow A.

7.3Secure the thermocouple in the rear of the gas control. (Do not over tighten). Turn the gas supply on and check the entire pipework and valve joints for any leaks.

8.MAIN INJECTOR

8.1Turn the gas supply off at the isolation device. Refer to Section 2, Replacing Parts to remove the main burner.

8.2Undo the compression nut from the feed pipe at the gas control under the appliance.

8.3Working from inside the firebox, remove the lock nut from the injector, see diagram 12 and withdraw the injector complete with the feed pipe from under the appliance.

12

AR0918

24

Image 24
Contents PR0848 Issue 2 February Ceramica ManhattanContents Appliance Commissioning Checklist Flue Check Pass FailGAS Check User Instructions GeneralLighting the Stove Turning OFF the StoveCleaning the Fire Handling & Disposal of Fire CeramicsFuel BED Arrangements Installation Details Flame Failure Device‘RUNNING IN’ ServicingInstallation Instructions Technical SpecificationSite Requirements Flue and Chimney RequirementsTimber Framed Buildings TOP Exit Guard SuppliedTOP Flue UP & OUT with Additional Bend ALL AppliancesOptional Extra Flue Lengths & Bends Nominal Actual Stainless AnthraciteInstallation of the GAS Supply VentilationAppliance Location Appliance requires no additional ventilationInstallation Control UpgradeSafety Precautions Installation of the StoveDo not FIX the Flue AT this Stage AR0490 Vertical & Horizontal Flue Table a TOP Exit Flue Vertical and Horizontal RestrictorsVertical Flue Height Horizontal Length Restrictor Size TOP Exit Vertical Flue Table a TOP Exit Vertical only Including OffsetRemove ANY Cardboard Fitment Remaining Vertical Height Restrictor SizeFuelbed Arrangements Lighting Commissioning CommissioningServicing / Fault Finding Charts Servicing InstructionsServicing Requirements Ignition Functional CheckFlame Failure Functional Check Pilot will not Stay LIT or Fire Goes OUT in USENo Spark Replacing Parts Main BurnerPilot Unit Ignition Lead Magnetic Safety Valve PiezoGAS Valve Main InjectorPrimary Aeration Plate Changing Between GAS TypesShort Spares List Service Records Member of the Stovax Group