INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
1.2 REAR FLUE 8526
Terminal dimensions:
395 x 200 x 200 mm (H x W x D)
Cut to length as required on site.
2
AR0630
Guard Supplied.
1.3 TOP EXIT
Two types of top exit flue terminal are available, horizontal and vertical. For a horizontal terminal, decide on the terminal position and measure the height from the top of the appliance to the centre of the required hole. For minimum and maximum flue dimensions see diagram 3.
Access must be either above or at the side of the installation to allow the flue to be assembled on top of the appliance. When a horizontal terminal is used, the vertical sections are assembled first, then the
Only the horizontal terminal section can be reduced in size.
Refer to Balanced Flue Technical Information for details of flue length.
1.4 TOP FLUE UP & OUT KIT (8523/8523AN)
Vertical from the top of the appliance then horizontally out. (See diagram 3.)
The basic kit comprises:
1 x 500mm vertical length
1 x 500mm terminal length (cut to length on site) 1 x 90 degree elbow
1 x wall plate
1 x 75mm restrictor fixing screws
The kit is the minimum required. Extra lengths may be added to the vertical and horizontal (see section 1.5), with reference to Diagram 3.
Extra lengths may be added (see section 1.5), with reference to diagram 3 and the installation instructions of the appliance.
3
AR1619
Refer to Table A under 3.2, Installation for identifying when to use the restrictor.
9