Stovax Ceramica Manhattan Wood Stove manual Lighting

Page 18

INSTALLATION INSTRUCTIONS

INSTALLATION

5.4Place the second ash panel to the right of the first, with the pointed end of the panel fitting into the V shape. This panel should locate on the screw holes of the burner skin. Ensure that both logs are horizontal to the burner ports.

19

AR1615

5.5Place log E across from the rear of log A to log C on the right hand side. Again, there are cut-outs for location. The front of the log should sit on the front ash panels and should fit tight to log C. See diagram 20.

20

AR1616

5.6Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four dome nuts and tool supplied, do not overtigthen the nuts.

NEVER OPERATE THE STOVE WHEN THE DOOR IS

REMOVED.

6.LIGHTING

6.1Full instructions are given in the User section under Lighting the Stove.

18

Image 18
Contents PR0848 Issue 2 February Ceramica ManhattanContents Appliance Commissioning Checklist Flue Check Pass FailGAS Check Lighting the Stove User InstructionsGeneral Turning OFF the StoveCleaning the Fire Handling & Disposal of Fire CeramicsFuel BED Arrangements ‘RUNNING IN’ Installation DetailsFlame Failure Device ServicingInstallation Instructions Technical SpecificationSite Requirements Flue and Chimney RequirementsTimber Framed Buildings TOP Exit Guard SuppliedOptional Extra Flue Lengths & Bends TOP Flue UP & OUT with Additional BendALL Appliances Nominal Actual Stainless AnthraciteAppliance Location Installation of the GAS SupplyVentilation Appliance requires no additional ventilationSafety Precautions InstallationControl Upgrade Installation of the StoveDo not FIX the Flue AT this Stage AR0490 Vertical & Horizontal Flue Table a TOP Exit Flue Vertical and Horizontal RestrictorsVertical Flue Height Horizontal Length Restrictor Size Remove ANY Cardboard Fitment Remaining TOP Exit Vertical FlueTable a TOP Exit Vertical only Including Offset Vertical Height Restrictor SizeFuelbed Arrangements Lighting Commissioning CommissioningServicing Requirements Servicing / Fault Finding ChartsServicing Instructions Ignition Functional CheckFlame Failure Functional Check Pilot will not Stay LIT or Fire Goes OUT in USENo Spark Replacing Parts Main BurnerPilot Unit Ignition Lead GAS Valve Magnetic Safety ValvePiezo Main InjectorPrimary Aeration Plate Changing Between GAS TypesShort Spares List Service Records Member of the Stovax Group