Stovax Ceramica Manhattan Wood Stove manual Flame Failure Device, ‘Running In’, Servicing

Page 6

USER INSTRUCTIONS

7.4Place log D across from the rear log A to log B on the left- hand side. There are cut-outs in both logs for location. See diagram 5.

5

AR1613

7.5There are two ash panels which lay across the front of the burner skin. Place the panel with the flat edge facing the left side of the firebox. There are location holes on this log which fit over the screw holes of the burner skin.

6

AR1614

7.6Place the second ash panel to the right of the first, with the pointed end of the panel fitting into the V shape. This panel should locate on the screw holes of the burner skin. Ensure that both logs are horizontal to the burner ports.

7

AR1615

7.7Place log E across from the rear of log A to log C on the right hand side. Again, there are cut-outs for location. The front of the log should sit on the front ash panels and should fit tight to log C. See diagram 8.

8

AR1616

7.8Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four dome nuts and tool supplied. Do not overtigthen the nuts.

NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVED.

8.THE FLAME FAILURE DEVICE

8.1This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermocouple.

9.‘RUNNING IN’

9.1The surface coating on your GAZCO fires will "burn off" during the first 24 hour of use, producing a harmless and temporary odour. This will disappear after the short period of use. If the odour persists, ask your installer for advice.

10.SERVICING

10.1The fire must be serviced every 12 months by a qualified Gas Engineer. In all correspondence, always quote the appliance type and serial number, which may be found on the data badge.

11.INSTALLATION DETAILS

11.1To assist in any future correspondence, your installer should have completed the commissioning sheet at the front of this manual. This records the essential installation details of this appliance. In all correspondence always quote the Model No. and Serial No.

6

Image 6
Contents PR0848 Issue 2 February Ceramica ManhattanContents Appliance Commissioning Checklist Flue Check Pass FailGAS Check Lighting the Stove User InstructionsGeneral Turning OFF the StoveCleaning the Fire Handling & Disposal of Fire CeramicsFuel BED Arrangements ‘RUNNING IN’ Installation DetailsFlame Failure Device ServicingInstallation Instructions Technical SpecificationSite Requirements Flue and Chimney RequirementsTimber Framed Buildings TOP Exit Guard SuppliedOptional Extra Flue Lengths & Bends TOP Flue UP & OUT with Additional BendALL Appliances Nominal Actual Stainless AnthraciteAppliance Location Installation of the GAS SupplyVentilation Appliance requires no additional ventilationSafety Precautions InstallationControl Upgrade Installation of the StoveDo not FIX the Flue AT this Stage AR0490 Vertical & Horizontal Flue Table a TOP Exit Flue Vertical and Horizontal RestrictorsVertical Flue Height Horizontal Length Restrictor Size Remove ANY Cardboard Fitment Remaining TOP Exit Vertical FlueTable a TOP Exit Vertical only Including Offset Vertical Height Restrictor SizeFuelbed Arrangements Lighting Commissioning CommissioningServicing Requirements Servicing / Fault Finding ChartsServicing Instructions Ignition Functional CheckFlame Failure Functional Check Pilot will not Stay LIT or Fire Goes OUT in USENo Spark Replacing Parts Main BurnerPilot Unit Ignition Lead GAS Valve Magnetic Safety ValvePiezo Main InjectorPrimary Aeration Plate Changing Between GAS TypesShort Spares List Service Records Member of the Stovax Group