7.8.5Place one large log (No. 6) so that it rests on top of the rear and front logs to the LH side. Place the other large log (No. 6) so that it rests on top of the rear and front logs on the RH side and log (No. 8) so that it bridges the centre gap as shown. See diagram 26.

26

AR1281

7.9 Log & Driftwood Layout – Tahoe

It may be necessary to make small changes to the log positioning in order to achieve the most pleasing flame effect but the following guidelines should be followed.

7.9.1Refer to the log identification chart and identify the numbers corresponding to the logs that have been supplied. See diagram 27.

27

8

7.9.2Place a cone (No. 14) in the centre at the rear edge of the tray and place one log (No. 13) at each side of the cone. Place one log (No. 11) along the front of the tray at each side of the pilot. See diagram 28.

28

7.9.3Place the burnt effect log (No. B1) in the centre of the tray. See diagram 29.

29

AR1283

7.9.4Place one log (No. 8) in the centre so that it rests on the rear cone and the pilot shield. See diagram 30.

30

AR1284

7.9.5Place one log (No. 11) so that it rests on the LH front log and the burnt log. Place another log (No. 7) so that it rests on the RH front log and the burnt log. See diagram 31.

31

AR1285

AR1282

10

Image 10
Contents Aspen, Chamonix & Tahoe Decorative Gas Basket Fires Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check Lighting the Appliance User InstructionsGeneral Turning the Appliance OFFUpgrading Your Fire Cleaning the FireArrangement of Fuel BED Components Coal & Pebble Layout Small Aspen & Chamonix Coal & Pebble Layout Medium Chamonix, Large Aspen & Chamonix Coal & Pebble Layout TahoeLog & Driftwood Layout Small Aspen & Chamonix AR1276 Log & Driftwood Layout Tahoe Running Oxygen Depletion SensorFlame Failure Device ServicingHigh Site Requirements Installation InstructionsInstallation of the GAS Supply Flue and Chimney RequirementsControl Upgrade Appliance LocationInstallation InstallationSafety Precautions UnpackingArrangement of Fuel BED Components AR1265 AR1268 AR1277 AR1274 AR1278 AR1285 Commissioning CommissioningServicing Instructions Servicing / Fault Finding ChartsServicing Requirements Ignition Functional Check Ignition Functional CheckFault Finding Charts Flame Failure Functional CheckFire Removal Replacing PartsIgnition Lead Piezo ODS Pilot UnitMain Injector Magnetic UnitPrimary Aeration Plate GAS Valve Engine Assembly Air Box Gasket Pilot Assembly DatabadgeChanging Between GAS Types Natural Gas Components LPG Gas ComponentsService Records Member of the Stovax Group