Stovax (P)8136**UC, (P)8120**UC, (P)8144**UC, (P)8143**UC, (P)8135**UC, (P)8128**UC manual AR1276

Page 9

USER INSTRUCTIONS

7.7.4Place log (No. 7) along the LH side of the tray, log (No. 9) along the RH side of the tray and place logs (No. 8 and 11) along the front of the tray as shown. Place the cone (No. 14) on the LH side of the burnt log. See diagram 20.

20

AR1276

7.7.5Place the large log (No. 6) so that it rests on top of the rear and front logs to the LH side, Place log (No. 7) on the RH side and log (No. 8) so that it bridges the centre gap as shown. See diagram 21.

21

AR1277

7.8 Log & Driftwood Layout – Medium Chamonix, Large Aspen & Chamonix

It may be necessary to make small changes to the log positioning in order to achieve the most pleasing flame effect but the following guidelines should be followed.

7.8.1Refer to the log identification chart and identify the numbers corresponding to the logs that have been supplied. See diagram 22.

22

8

7.8.2Place the two logs (No.13) on top of the beads as shown. See diagram 23.

23

AR1278

7.8.3Place the large log (No. 1) so that it sits on top of the previous two logs. Place the burnt effect log (No. A1) in the centre of the tray as shown. Place one log (No. 7) along each side of the tray, another log (No. 7) along the front LH side and a log (No. 8) along the front RH side of the tray. See diagram 24.

24

AR1279

7.8.4Place two cones (No. 14), one in the RH front corner and the other at the LH side of the burnt log. See diagram 25.

25

AR1280

9

Image 9
Contents Aspen, Chamonix & Tahoe Decorative Gas Basket Fires Contents Appliance Commissioning Checklist Flue Check Pass FailGAS Check General User InstructionsLighting the Appliance Turning the Appliance OFFCleaning the Fire Upgrading Your FireArrangement of Fuel BED Components Coal & Pebble Layout Small Aspen & Chamonix Coal & Pebble Layout Tahoe Coal & Pebble Layout Medium Chamonix, Large Aspen & ChamonixLog & Driftwood Layout Small Aspen & Chamonix AR1276 Log & Driftwood Layout Tahoe Flame Failure Device Oxygen Depletion SensorRunning ServicingHigh Installation of the GAS Supply Installation InstructionsSite Requirements Flue and Chimney RequirementsAppliance Location Control UpgradeSafety Precautions InstallationInstallation UnpackingArrangement of Fuel BED Components AR1265 AR1268 AR1277 AR1274 AR1278 AR1285 Commissioning CommissioningServicing / Fault Finding Charts Servicing InstructionsServicing Requirements Ignition Functional Check Ignition Functional CheckFlame Failure Functional Check Fault Finding ChartsReplacing Parts Fire RemovalIgnition Lead ODS Pilot Unit PiezoMagnetic Unit Main InjectorPrimary Aeration Plate Engine Assembly Air Box Gasket Pilot Assembly Databadge GAS ValveChanging Between GAS Types LPG Gas Components Natural Gas ComponentsService Records Member of the Stovax Group