Stovax (P)8135**UC, (P)8120**UC, (P)8136**UC, (P)8144**UC, (P)8143**UC, (P)8128**UC manual AR1278

Page 20

INSTALLATION INSTRUCTIONS

INSTALLATION

5.8 Log & Driftwood Layout – Medium Chamonix, Large Aspen & Chamonix

It may be necessary to make small changes to the log positioning in order to achieve the most pleasing flame effect but the following guidelines should be followed.

5.8.1Refer to the log identification chart and identify the numbers corresponding to the logs that have been supplied. See diagram 23.

23

8

5.8.2Place the two logs (No.13) on top of the beads as shown. See diagram 24.

24

AR1278

5.8.3Place the large log (No. 1) so that it sits on top of the previous two logs. Place the burnt effect log (No. A1) in the centre of the tray as shown. Place one log (No. 7) along each side of the tray, another log (No. 7) along the front LH side and a log (No. 8) along the front RH side of the tray. See diagram 25.

25

AR1279

5.8.4Place two cones (No. 14), one in the RH front corner and the other at the LH side of the burnt log. See diagram 26.

26

AR1280

5.8.5Place one large log (No. 6) so that it rests on top of the rear and front logs to the LH side. Place the other large log (No. 6) so that it rests on top of the rear and front logs on the RH side and log (No. 8) so that it bridges the centre gap as shown. See diagram 27.

27

AR1281

20

Image 20
Contents Aspen, Chamonix & Tahoe Decorative Gas Basket Fires Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail User Instructions GeneralLighting the Appliance Turning the Appliance OFFArrangement of Fuel BED Components Cleaning the FireUpgrading Your Fire Coal & Pebble Layout Small Aspen & Chamonix Coal & Pebble Layout Medium Chamonix, Large Aspen & Chamonix Coal & Pebble Layout TahoeLog & Driftwood Layout Small Aspen & Chamonix AR1276 Log & Driftwood Layout Tahoe Oxygen Depletion Sensor Flame Failure DeviceRunning ServicingHigh Installation Instructions Installation of the GAS SupplySite Requirements Flue and Chimney RequirementsControl Upgrade Appliance LocationInstallation Safety PrecautionsInstallation UnpackingArrangement of Fuel BED Components AR1265 AR1268 AR1277 AR1274 AR1278 AR1285 Commissioning CommissioningServicing Requirements Servicing / Fault Finding ChartsServicing Instructions Ignition Functional Check Ignition Functional CheckFault Finding Charts Flame Failure Functional CheckIgnition Lead Replacing PartsFire Removal Piezo ODS Pilot UnitPrimary Aeration Plate Magnetic UnitMain Injector Changing Between GAS Types Engine Assembly Air Box Gasket Pilot Assembly DatabadgeGAS Valve Natural Gas Components LPG Gas ComponentsService Records Member of the Stovax Group