7.9.6Place the two thin logs (No. 12), one at each side sitting on the tray and resting against the previously positioned logs. Place one log (No. 9) at the LH rear resting on the base log, and one log (No. 8) at the RH rear. See diagram 32.

32

AR1286

8.OXYGEN DEPLETION SENSOR

8.1The appliance is fitted with an oxygen sensitive pilot system that will act to cut off the gas supply to the fire should the oxygen in the room fall below its normal level. If the fire is turned off by this device, it usually indicates that there is a problem with the flue system, and this should be inspected by a qualified engineer.

Do not attempt to use the fire until an engineer says it is safe to do so.

This device is not a substitute for an independently mounted carbon monoxide detector.

9.FLAME FAILURE DEVICE

9.1This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot goes out and fails to heat the thermocouple.

10.RUNNING IN

10.1The surface coating on the fuel effect used in your GAZCO fire will "burn off" during the first few hours of use producing a harmless and temporary odour. This will disappear after a short period of use. If the odour persists, ask your installer for advice.

11.SERVICING

11.1The fire must be serviced every 12 months by a qualified Gas Engineer. In all correspondence always quote the appliance type and the serial number which may be found on the databadge, located on a chain underneath the control valve.

11

Image 11
Contents Aspen, Chamonix & Tahoe Decorative Gas Basket Fires Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail Turning the Appliance OFF User InstructionsGeneral Lighting the ApplianceArrangement of Fuel BED Components Cleaning the FireUpgrading Your Fire Coal & Pebble Layout Small Aspen & Chamonix Coal & Pebble Layout Tahoe Coal & Pebble Layout Medium Chamonix, Large Aspen & ChamonixLog & Driftwood Layout Small Aspen & Chamonix AR1276 Log & Driftwood Layout Tahoe Servicing Oxygen Depletion SensorFlame Failure Device RunningHigh Flue and Chimney Requirements Installation InstructionsInstallation of the GAS Supply Site RequirementsAppliance Location Control UpgradeUnpacking InstallationSafety Precautions InstallationArrangement of Fuel BED Components AR1265 AR1268 AR1277 AR1274 AR1278 AR1285 Commissioning CommissioningServicing Requirements Servicing / Fault Finding ChartsServicing Instructions Ignition Functional Check Ignition Functional CheckFlame Failure Functional Check Fault Finding ChartsIgnition Lead Replacing PartsFire Removal ODS Pilot Unit PiezoPrimary Aeration Plate Magnetic UnitMain Injector Changing Between GAS Types Engine Assembly Air Box Gasket Pilot Assembly DatabadgeGAS Valve LPG Gas Components Natural Gas ComponentsService Records Member of the Stovax Group