Stovax (P)8135**UC User Instructions, General, Lighting the Appliance, Turning the Appliance OFF

Page 4

USER INSTRUCTIONS

1.GENERAL

1.1Installation and servicing must only be carried out by a competent person.

1.2In all correspondence, please quote the appliance type and serial number, which can be found on the databadge located on a chain beneath the control valve.

1.3Ensure that curtains are not positioned above the fire, and that there is a 300mm minimum clearance between the sides of the fire and any curtains.

1.4This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and your local Gazco dealer. Please consult with your local Gazco dealer if you have any questions. In all correspondence always quote the Model Number and Serial Number.

2.LIGHTING THE APPLIANCE

2.1Locate the control valve on the appliance. There are two control knobs on the valve, the right hand knob controls the pilot ignition and the left hand knob controls the main burner.

2.2If your appliance has already been upgraded to battery remote control, please refer to the instructions provided with the upgrade to operate the remote control. The following instructions will work for either situation.

2.3Ensure that the left-hand control knob is pointing to off ( ).

2.4Ensure that the right hand control knob is pointing to off ( ).

2.5Press in the right hand control knob and rotate it anti- clockwise until a click is heard (keep pressing in) and the knob is pointing to pilot ( ). The pilot should now light. If the pilot has not lit, repeat the procedure until it does.

2.6Keep the control knob pressed for 10 seconds and then release it, the pilot should stay alight. If the pilot goes out, repeat the procedures until it does.

2.7If the pilot will not light after repeated attempts, contact the retailer or installer from whom the appliance was purchased.

2.8Turn the right hand control to point to main burner ( ). The appliance can now be controlled using the left hand control knob.

2.9Turn the left hand control knob to point to low fire ( ), the main burner will light on low. The burner can now be controlled between low and high settings. Turn the control

knob anticlockwise to increase the flame height and clockwise to decrease the flame height.

THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20 MINUTES.

3.TURNING THE APPLIANCE OFF

3.1To turn the fire off, locate the control valve, turn the left- hand control knob until it points to off (). The main burner will go out leaving the pilot burning.

3.2To turn the pilot off, locate the control valve, turn the right hand control knob until it points to off (), the pilot will go out.

3.3IF THE FIRE IS EXTINGUISHED OR GOES OUT IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RE-LIGHT.

3.4After the fire has been turned off, the gas left in the burner will continue to burn, causing a crackling or popping noise. This is quite normal and will last up to one minute.

4.LIGHTING THE FIRE WITH A MATCH

If the pilot does not ignite as described in Section 2, it may be lit with a match.

1

4.1Press in the right hand control knob and rotate it anti- clockwise until a click is heard (keep pressing in) and the knob is pointing to pilot (), apply a lighted match to the pilot hood, see diagram 1.

4.2When the pilot is alight, extinguish the match and continue to depress for 5 to 10 seconds.

4.3The fire may now be controlled as previously described.

4

Image 4
Contents Aspen, Chamonix & Tahoe Decorative Gas Basket Fires Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check User Instructions GeneralLighting the Appliance Turning the Appliance OFFUpgrading Your Fire Cleaning the FireArrangement of Fuel BED Components Coal & Pebble Layout Small Aspen & Chamonix Coal & Pebble Layout Medium Chamonix, Large Aspen & Chamonix Coal & Pebble Layout TahoeLog & Driftwood Layout Small Aspen & Chamonix AR1276 Log & Driftwood Layout Tahoe Oxygen Depletion Sensor Flame Failure DeviceRunning ServicingHigh Installation Instructions Installation of the GAS SupplySite Requirements Flue and Chimney RequirementsControl Upgrade Appliance LocationInstallation Safety PrecautionsInstallation UnpackingArrangement of Fuel BED Components AR1265 AR1268 AR1277 AR1274 AR1278 AR1285 Commissioning CommissioningServicing Instructions Servicing / Fault Finding ChartsServicing Requirements Ignition Functional Check Ignition Functional CheckFault Finding Charts Flame Failure Functional CheckFire Removal Replacing PartsIgnition Lead Piezo ODS Pilot UnitMain Injector Magnetic UnitPrimary Aeration Plate GAS Valve Engine Assembly Air Box Gasket Pilot Assembly DatabadgeChanging Between GAS Types Natural Gas Components LPG Gas ComponentsService Records Member of the Stovax Group