Stovax GAZCO Linea Balanced Flue Convector Fire manual

Page 11

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

5

VETRO / PLANO DIMENSIONS

AR1327

4.4All combustible materials must be removed from behind the appliance. See diagram 6.

6

Combustible material to be removed around centre

 

line of flue. Shown as shaded area

AR1328

4.5The Linea may be mounted at any height, however, there must be a minimum clearance of 150mm (6") between the bottom edge of the appliance and the floor. To achieve this, the minimum flue height for each front is shown in diagram 7.

7 MINIMUM HEIGHT OF FLUE FROM FLOOR LEVEL

VETRO / PLANO

DESIGNIO

AR1324

11

Image 11
Contents Linea Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail Lighting the Linea with Hand SET User InstructionsGeneral Cleaning the Linea To set the room temperatureUser Instruction Fire will not Light Battery ReplacementPacking Checklist Installation InstructionsTechnical Specification Flue and Chimney Requirements Site RequirementsAppliance Location GAS SupplyMinimum Height of Flue from Floor Level Vetro / Plano Installation of the Appliance InstallationSafety Precautions Do not Over TIGHTEN. do not Deform the Rear of the Appliance Have YOU Purged the GAS SUPPLY? CommissioningServicing Requirements Servicing / Fault Finding ChartsServicing Instructions Flame Failure Functional Check Ignition Functional CheckPilot Burner Replacing PartsMain Burner Pilot UnitThermocouple Pilot InjectorElectrode Ignition Lead Magnetic Safety ValveMain Injector GAS Valve Control BOXChanging Between GAS Types Control Bracket AssemblyButane Short Spares ListService Records Member of the Stovax Group