USER INSTRUCTIONS

2.5 To set the room temperature

2.5.1Following on from section 2.4, once the room temperature is flashing on the display, it can be set.

2.5.2Press either the () button (10) or the ( ) button (13) to either increase or decrease the temperature.

2.5.3Press the SET button (12) once you have set the temperature as desired.

If the SET button (12) is not pushed the temperature display will stop flashing and remain unchanged.

2.6To change from Automatic to Manual mode.

2.6.1The hand set display will show AUTO (8).

2.6.2Press the SET button (12) once and the word MANUAL will flash.

2.6.3Press the SET button (12) again and the word MANUAL will stop flashing.

You are now in Manual mode.

2.7 Low battery display (Hand Set)

The low battery symbol (6) will appear on the hand set when the batteries require replacement.

2

2.8 Lighting the Linea (Touch Pad)

2.8.1Press the ON / OFF button (1) once and the red LED will flash. The pilot will now light. This should take about 10 seconds.

If the pilot does not light press the ON / OFF button (1) again to reset the control unit and repeat step 1 above. Before the burner can be lit wait for the audible click.

2.9 To adjust the flame height (Touch Pad)

2.9.1Once the pilot has lit press the () button (2) and the burner will light.

2.9.2Press either of the ( ) buttons (2/3) to adjust the height of the flames.

2.10 To turn the Linea off (Touch Pad)

2.10.1Press the ON / OFF button (1) once and the Linea will turn off.

3. CLEANING THE LINEA

ENSURE THE APPLIANCE IS COLD BEFORE PROCEEDING.

3.1The outside casing of the Linea should be cleaned using a damp cloth.

3.2To clean the glass panel, remove the decorative front as detailed in the instructions supplied with front.

3.3Remove the glass panel by unscrewing the nine pozidrive screws. See diagram 3

3

AR1339

3.4Use a damp cloth and warm soapy water. Ensure the glass is dry before re-assembling.

3.5Ensure that the fibreglass seal on the firebox is intact then hook the location tabs over the hooks on the top of the firebox. Replace the nine screws working from the top down, three long ones in the bottom holes. Tighten the screws evenly.

NEVER OPERATE THE APPLIANCE WHEN THE GLASS PANEL IS REMOVED OR BROKEN.

5

Image 5
Contents Linea Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail Lighting the Linea with Hand SET User InstructionsGeneral Cleaning the Linea To set the room temperatureUser Instruction Fire will not Light Battery ReplacementPacking Checklist Installation InstructionsTechnical Specification Flue and Chimney Requirements Site RequirementsAppliance Location GAS SupplyMinimum Height of Flue from Floor Level Vetro / Plano Installation of the Appliance InstallationSafety Precautions Do not Over TIGHTEN. do not Deform the Rear of the Appliance Have YOU Purged the GAS SUPPLY? CommissioningServicing Requirements Servicing / Fault Finding ChartsServicing Instructions Flame Failure Functional Check Ignition Functional CheckMain Burner Replacing PartsPilot Unit Pilot BurnerThermocouple Pilot InjectorElectrode Ignition Lead Magnetic Safety ValveMain Injector GAS Valve Control BOXChanging Between GAS Types Control Bracket AssemblyButane Short Spares ListService Records Member of the Stovax Group