SERVICING INSTRUCTIONS

REPLACING PARTS

1.GENERAL

1.1All principal components can be replaced without removing the appliance from its installation, although it is essential that the gas supply to the appliance is turned off at the isolation device before proceeding further.

1.2If for any reason the flue has to be removed from the appliance, the seal must be replaced in the inner spigot.

1.3If access to the controls is restricted, the whole control assembly and wiring loom can be removed and serviced outside the Linea, refer to section 14 for further details.

2.MAIN BURNER

2.1Remove the front from the appliance. (Refer to the instructions supplied with the decorative front)

2.2Remove the glass frame, note the orientation of the screws. The three long silver screws locate only in the bottom of the frame. See diagram 1, arrow C.

1

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

C

C

 

 

 

AR1338

 

 

 

 

 

 

 

 

 

 

 

2.3Compress the burner retaining spring towards the burner. See diagram 2.

2

AR1340

2.4Raise the burner from the slot in the bracket, pull the burner forward and slide to the left to clear the injector. Take care not to lose the spring.

2.5Replace in reverse order ensuring the spring is located over the stud on the burner and the tab on the bracket.

3. PILOT UNIT

The main frame, glass frame and main burner need only be removed if the pilot burner is to be replaced. If only the pilot injector, electrode or thermocouple is to be replaced they can be accessed from under the appliance.

The pilot assembly consists of four components, which can be individually changed, these are:

1)Pilot burner bracket.

2)Pilot injector

3)Electrode

4)Thermocouple.

4.PILOT BURNER

4.1Remove the main front by referring to the instructions supplied with the decorative front.

4.2Remove the glass frame from the appliance. See diagram 1 arrow C.

4.3Remove the main burner by compressing the spring on the lefthand side of the burner. See diagram 2. Raise the burner forward and slide to the left to clear the injector. Take care not to lose the spring.

4.4Working underneath the appliance, remove the lower cover. See diagram 3.

3

AR1341

4.5Remove the thermocouple, pilot pipe and electrode as described in the sections 5 to 7.

4.6Remove the two screws retaining the pilot burner. See diagram 4.

17

Image 17
Contents Linea Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail Lighting the Linea with Hand SET User InstructionsGeneral Cleaning the Linea To set the room temperatureUser Instruction Fire will not Light Battery ReplacementPacking Checklist Installation InstructionsTechnical Specification Flue and Chimney Requirements Site RequirementsAppliance Location GAS SupplyMinimum Height of Flue from Floor Level Vetro / Plano Installation of the Appliance InstallationSafety Precautions Do not Over TIGHTEN. do not Deform the Rear of the Appliance Have YOU Purged the GAS SUPPLY? CommissioningServicing Requirements Servicing / Fault Finding ChartsServicing Instructions Flame Failure Functional Check Ignition Functional CheckMain Burner Replacing PartsPilot Unit Pilot BurnerThermocouple Pilot InjectorElectrode Ignition Lead Magnetic Safety ValveMain Injector GAS Valve Control BOXChanging Between GAS Types Control Bracket AssemblyButane Short Spares ListService Records Member of the Stovax Group