InSinkErator CWT-00, F-C1100 Installing the Cold only Faucet, Installing the Water Tank

Page 8

2

Follow these steps for installing chilled water tank with a cold only faucet.

INSTALLING THE COLD ONLY FAUCET

A

Property Damage: Do not pinch or break copper tubing. Do not distort the last 1 inch of tubing.

Unpack faucet components.

On a firm, flat surface, carefully straighten the copper tubing.

Ensure that the black O-ring is properly seated in the base of the faucet (the groove on the underside of the faucet base).

B

An assistant may be needed to hold

the faucet in place

while securing the base.

Feed tube down through sink hole until the base is at rest.

From under the sink, place the semi-circular mounting plate onto the threaded stud.

Place hex nut onto the threaded stud. Ensure faucet is at desired angle.

Insert screwdriver into hole on side of hex tool (creating a “T”), and use tool to tighten nut and secure faucet.

3

INSTALLING THE WATER TANK

A

Inlet

Property Damage: All tubes must be cut

squarely with no burrs.

Attach supplied quick connect elbow to end of supplied white 1/4" tube.

Attach quick connect elbow to water Inlet on front of chilled water tank.

Measure distance from water inlet on chilled water tank to water supply valve (See Step 3). Carefully trim white 1/4" tube, allowing ample slack in tubing.

B

Inlet

Property Damage: Do not pinch or break tubing.

Do not distort the last 1 inch of tubing.

Pull on connection to ensure fully engaged.

Attach supplied quick connect elbow to end of supplied blue 1/4" tube.

Attach quick connect elbow with blue tube to water Outlet on front of chilled water tank.

Measure distance from chilled water tank outlet to water supply line on faucet. Carefully trim blue tube to correct length.

Using quick connect elbow, connect blue tube to faucet water supply.

8

Image 8
Contents Chilled Water Tank & Cold Only Faucet What YOU should Know Before YOU Begin Cold Only Faucet Package ComponentsWhite Tubing Blue Tubing On top of chilled water tank which Could obstruct the fan ApreparationShown with optional filtration Installing the Water Tank Water ConnectionRemove existing Y quick-connect fitting and discard Do not distort the last 1 inch of tubingFill Tank & Connect Power Overview of a Typical Installation with Cold Only Faucet PreparationInstalling the Cold only Faucet Install a T-fitting not included Onto the cold water supply lineWith 1/4 compression fitting White 1/4 tube into the 1/4Warranty Information CWT-00 Tank Year warranty C1100 FaucetCare and USE On the front of the unitReplace all cut, loose or split tubing To the OFF positionTroubleshooting Filtration Issues Filtration available as an optionManual del propietario Sierra perforadora / sacabocados Llave de plomeríaComponentes DEL Paquete Cómo Utilizar Este Manual DE InstruccionesPreparación Instalación DEL Tanque DE Agua Conexión DE AguaAbra el suministro de agua fría Pulse la palanca del suministro deAgua fría y manténgala presionada Hasta que salga agua del surtidor279 Instalación DEL Grifo DE Agua Fría Llenado DEL Tanque Y Conexión DEL Suministro EléctricoInformación Sobre LA Garantía Tanque CWT-00 Años de garantía Grifo C1100Flojos o agrietados Cuidado Y USOLa unidad inmediatamente El agua no está fría Solución DE ProblemasProblemas DE Filtración Filtración disponible a elección 800.558.5700