InSinkErator F-C1100, CWT-00 Install a T-fitting not included, Onto the cold water supply line

Page 9

4

Follow these steps for installing chilled water tank with a cold only faucet.

WATER CONNECTION

A

With no filtration system:

Install a T-fitting (not included)

 

onto the cold water supply line.

To “Inlet” on front of

Install dedicated water control valve

chilled water tank

with 1/4" compression fitting.

 

 

Attach remaining end of the supplied

 

white 1/4" tube into the 1/4"

 

compression fitting and tighten.

Property Damage: Join remaining tube

 

to cold water supply only. Water supply valves

 

must not prevent backward flow.

 

A Brass Nut

Ferrule

Brass Inse

Property Damage: Join remaining tube

to cold water supply only. Water supply valves

must not prevent backwards flow.

With optional InSinkErator filtration system:

For filtration installation instructions, see installation guide packed with the system.

Install a T-fitting (not included) onto the cold water supply line.

Install dedicated water control valve with 3/8" compression fitting.

Install brass nut, ferrule and tube insert at the end of the white 3/8" tube from filter.

Insert the white 3/8" tube into the 3/8" compression fitting and tighten.

5

FILL TANK & CONNECT POWER

A

Turn on the cold water supply.

 

Depress the faucet handle and

 

hold it until water flows from the

 

spout.

 

Allow water to run for at least 60

 

seconds after water begins to flow

 

from faucet.

 

Property Damage: Before plugging in

 

chilled water tank, check for leaks in all

 

water supply connections.

B

Property Damage: A standard grounded outlet

is required under the sink. Do not use an

extension cord set with the chilled water tank.

Check all connections to ensure they are tight and that there are no leaks.

Plug in chilled water tank.

Prior to drinking water from the chilled water tank, run the water for at least 5 minutes to flush lines.

Allow up to 60 minutes for

water to reach target temperature.

9

Image 9
Contents Chilled Water Tank & Cold Only Faucet What YOU should Know Before YOU Begin Package Components White Tubing Blue TubingCold Only Faucet Apreparation Shown with optional filtrationOn top of chilled water tank which Could obstruct the fan Water Connection Installing the Water TankRemove existing Y quick-connect fitting and discard Do not distort the last 1 inch of tubingFill Tank & Connect Power Preparation Overview of a Typical Installation with Cold Only FaucetInstalling the Cold only Faucet Onto the cold water supply line Install a T-fitting not includedWith 1/4 compression fitting White 1/4 tube into the 1/4CWT-00 Tank Year warranty C1100 Faucet Warranty InformationOn the front of the unit Care and USEReplace all cut, loose or split tubing To the OFF positionFiltration Issues Filtration available as an option TroubleshootingSierra perforadora / sacabocados Llave de plomería Manual del propietarioCómo Utilizar Este Manual DE Instrucciones Componentes DEL PaquetePreparación Conexión DE Agua Instalación DEL Tanque DE AguaPulse la palanca del suministro de Abra el suministro de agua fríaAgua fría y manténgala presionada Hasta que salga agua del surtidor279 Instalación DEL Grifo DE Agua Fría DEL Suministro Eléctrico Llenado DEL Tanque Y ConexiónTanque CWT-00 Años de garantía Grifo C1100 Información Sobre LA GarantíaCuidado Y USO La unidad inmediatamenteFlojos o agrietados Solución DE Problemas Problemas DE Filtración Filtración disponible a elecciónEl agua no está fría 800.558.5700