Hunter Fan 53177, 53173, 53175, 53172, 53171, 53176 What to Expect with Your Installation

Page 2

What to Expect with Your Installation

If you are unfamiliar with wiring, use a qualified electrician.

30 inches

 

from blade tip

 

to nearest wall

 

or obstruction

7 feet

 

 

from bottom

 

edge of blade

www.HunterFan.com 1.888.830.1326

Read and Save These Instructions

This product conforms to UL Standard 507.

WARNINGS

w.1 - To reduce the risk of fire, electrical shock, or personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.

Must be able to secure the fan to building structure or fan-rated outlet box

You may need a friend to help you.

Know your wiring

Ceiling angles greater than 34° will require an Angled Mounting Kit. See page 4 for details.

to the floor

Assess location

1 Standard Downrod

for ceilings 8-10 feet high

2 Shorter Downrod

for fans installed close to ceiling

3 Longer Downrod

for ceilings 10 feet or higher

w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.

w.3 - To reduce the risk of fire, electrical shock, or motor damage, use only Hunter Solid State Speed Controls.

w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

CAUTIONS

c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician.

Check box to see

 

fan weight

Assess ceiling angle

Select a downrod length

2

c.2 - Use only Hunter replacement parts.

M0094-01 • 02/19/14 • © Hunter Fan Company

Image 2
Contents Table of Contents ? ?What to Expect with Your Installation Tools Needed Mounting Options For angled ceilings, point Opening toward peak Ceiling BracketMake sure all four 4 bumpers Are still attached Preparation Downrod Hand Tighten Put the wires and downrod through FanWiring Canopy HolesBlades Switch Housing Feed the wire plug through the centerPull chain through the hole in the light kit Switch housing with the upper switchLight Kit Chain Install a bulb into eachKeeper Maintenance & Cleaning Customer serviceTroubleshooting Fan doesn’t work