Home Automation 1503 owner manual Display should show When Z6 ALM Stairwell on for

Page 44

Home Automation, Inc.

into the alarm state. So we program button 21 to turn unit 5 on for 5 minutes.

Press PROG, *(button), 2, 1, ENTER, UNIT-NUMBER, 5, TIME, 5, ON.

The display should show “WHEN Z6 ALM: - STAIRWELL ON FOR 5”.

Press ENTER to commit the program to memory.

SECURITY ARMING ACTIVATED BUTTONS

Certain buttons are automati- cally activated upon security arm- ing status changes. These buttons are activated when the system is put in the OFF, HOME, ASLEEP, or AWAY modes. When arming the system into the HOME, ASLEEP or AWAY modes, the button is activated after the EXIT DELAY. Programs that change the security arming mode activate these buttons. Quick arm- ing also activates these buttons.

Table 1 in the Appendix shows which buttons are activated by which zones.

EXAMPLE 3: Program the AWAY mode to turn off all lights and turn on the energy saver (unit 17). From Table 1, we determine that button 178 is activated when the security system is armed in the away mode.

Press PROG, *(button), 1, 7, 8, ENTER, ALL, OFF.

The display should read “WHEN AWAY: - ALL OFF”.

Press ENTER to commit the program to memory. Continue programming:

Press *(button), 1, 7, 8, ENTER, UNIT- NUMBER, 1, 7, ON.

The display should read “WHEN AWAY: - ENERGY SAVER ON”.

Press ENTER to commit the program to memory.

CONDITIONALIZED PROGRAMS

NOTE: In UL Listed Installa- tions, conditionalized programs shall not be used to control the security mode.

Timed programs and event buttons may be conditionalized such that the programmed command is only executed if the specified condition is true. Programs may be conditionalized by:

-Darkness (using the sunrise/ sunset calculation)

-Time Clock 1 - 3 on or off

-Zones closed/secure or open/in alarm

-Security mode (OFF, HOME, ASLEEP, or AWAY).

A program conditional may be specified by selecting the *IF option from the programming menu by pressing the * key. If no condi- tional is specified, the programmed command will always be executed when activated.

To allow a program to only be executed if it is light outside, i.e. after sunrise but before sunset, press *, AM.

To allow a program to only be executed if it is dark outside, i.e. after sunset but before sunrise, press *, PM.

42

Image 44
Contents HomeAutomation,Inc Alarm System CancelSECURITY-OFF, *, 2, ENTER, Code SECURITY-OFF, #, #, CodePage Contents Scrolling Through Names Show Programs Show ALL Programs Delete ProgramGoodbye Panic Button Over the Phone # # # # # # PC Access ALL OFF Status EventsSET-UP Model 1503 Default Settings Model Number Model 1503 VersionModel 1503 LC Serial NumberDifferences in models are noted in this manual Differences Between Version 2 and LC ModelsModel 1503 Version Model 1503-LC Things YOU should Know To silence the beeper, press the Cancel key For more information, seeSilencing Alarms That’s all there is to itTurning the Security System on Press the SECURITY-OFF keyExit Delay L E E PTo quick arm the system in the Away mode, press AWAY, Away Then enter your master code number Burglar Alarm Activated System now waits the Outside Siren Delay 60 seconds ALARM! Zone Name Tripped Emergency ALARM! Police EMG BTN TrippedMediately Please Respond ImmediatelyMedical EMG BTN Tripped Fire Alarm Fire EMG BTN TrippedSpond Immediately Alarm Reset Alarm Cancel Page Master Code Auxiliary CodesUsed is recorded in the event log Duress CodeModel 1503-LC cannot use Model 1102 Expansion Enclosures Module Types Appliance ModulesHouse Code X+3 House Code X+2113 Console will beep, and a ALL OFFMomentary ON/OFF Commands Temperature this is the air temperature read by the Pesm Freeze Alarm Temperature Control Appliances Model 1102 Expansion Enclosure Model1503Version2only Temperatures lo and hi tem- peratures All Lights On, All Off Program Storage Press the Prog keyPress the UNIT-NUMBER key Press 4 or the Show key 4 times, thenPress PROG, UNIT-NUMBER, 2, OFF Automatic Calculation of SUNRISE/ S U N S E TSince 600 PM is what we want, press Mmdd DAY Press 9 for weekends Press the Enter keyPress Prog key if you aren’t already in the Program menu If the display reads as above, pressNow press *, Asleep Press Cancel so that this program is not storedSome other programming sugges- tions Procedure for programming a button is Display will read Prog GO to BED Front Porch DIM EnterDisplay will read GO to BED ALL OFF Display will read RUN GO to BED Enter Cancel Press Show to see the second and third programs for ButtonPress Cancel twice to exit the Show Programs menu Display will read GO to BED Master AsleepPress TIME, 6, 0, 0, PM Press DATE-DAY, DATE-DAY, 8, Enter Example Program Button 2 to run at 600 PM every weekdayAppendix shows which buttons are activated for each zone Appendix shows which buttons are activated by which zones Display should show When Z6 ALM Stairwell on forDisplay should read When Away ALL OFF When Z1 ALM if DRK Unit 1 on Display ConditionalLIT DRKTime Clocks Light on178, Enter when away ALL OFF 178, Enter when away Unit 1 on Press PROG, *, 180, ENTER, UNIT-NUMBER, 1, ON, EnterPrograms for when security off DAYS, ENTER, Enter Show Programs Press the Show keyPress the Show key to see the next program in memory Press the SET-UP key to go back toShow Programs for ALL Unit Numbers Previous program in memoryPulse and Tone Phones Remote Phones Phone Access Denied Remote Lockout Goodbye Star * Cancel Repeat Message Model 1503 Version 2 onlyModel 1503 will say Home Control Enter Unit NUMBER, then Pound KEYOFF Temperature is 76 Degrees Main MenuUnit numbers 17 and 19 Control, then press the # keyModel 1503 will then confirm the new low setting ASLEEP, 3 AWAY, Star * CAN- CELExamples Model 1503 will say ButtonYou will then be returned to the main menu Enter your code numberFire Zone in ALARM, Trouble NOW or had Trouble Zone X Zone Type BypassedHad Trouble To hear the event log, press 7 from the main menuRecord MESSAGE, 8 Repeat Message Play ADDRESS, Star Cancel To Cancel from the message menu, pressGoodbye Panic Button Over the Phone # # #PC Access Fire Alarm Dial Order Freeze Alarm Dial OrderModel 1503 Voice DIAL-OUT Planner Dial OUT 1 onEmergency Numbers Fire Police Medical Other instructionsHome Phone Code againDigital Dialer To turn all lights off, press SET Time SET DateTo set up your CODES, press SET-UP, 1Codes Display will request yourRemember Your NEW Code Through 7 for SundayThere are 4 auxiliary codes Auxiliary Code ENTER. To remove a code, enter 0000 in its placeMode OFF, press a 0 then press Enter Access the system from a lo- cal phonePress Show to advance the display to Exit Delay House Code HouseNumber Default setting for ENTRY/ Exit Chime is YES Default setting for Quick ARM Enabled is no To exit the set-up facility, press Default setting for TELE- Phone Access is onDefault setting for Answer Outside CALL? is YES Default for Remote Commands OK? is YES Factory default for Rings Before Answer isDefault dial type is Tone Dial TypePhone numbers can be up to 16 digits Dial OUT 1 on Dial OUT 1 OFFDial OUT Number Dial OUT 2 on Dial OUT 2 OFF Dial OUT Number Dial OUT 3 on Dial OUT 3 OFFSame as Dial OUT Number Dial OUT Number Dial OUT 4 on Dial OUT 4 OFFInstaller Name Number Do not return to a burning houseFederal Communications COMMIS- Sion Notice Canadian Department of COMMUNI- Cations Notice

1503 specifications

Home Automation 1503 is a state-of-the-art system designed to elevate the standards of modern living by integrating advanced technology into everyday activities within the home. This comprehensive solution seamlessly connects various household devices, allowing users to control them through a central interface, typically accessible via smartphones, tablets, or dedicated control panels.

One of the hallmark features of Home Automation 1503 is its interoperability. The system is compatible with a wide array of devices, ranging from lighting and HVAC systems to security cameras and smart appliances. This ensures that homeowners can create a cohesive and interconnected environment tailored to their specific needs.

The technologies underpinning Home Automation 1503 include wireless communication protocols such as Wi-Fi, Zigbee, and Z-Wave. These protocols facilitate reliable communication between devices, ensuring that commands are transmitted quickly and accurately. Additionally, the system employs AI and machine learning algorithms to create smart environments that adapt to user preferences, enhancing convenience and energy efficiency.

Another significant characteristic of Home Automation 1503 is its user-friendly interface. The system often features customizable dashboards, enabling users to monitor and manage their home from a single screen. Voice control capabilities, integrated with popular virtual assistants such as Amazon Alexa or Google Assistant, allow for hands-free operation, making everyday tasks even more convenient.

Security is a top priority in Home Automation 1503. The system supports advanced security features like smart locks, motion sensors, and video surveillance, all of which can be monitored remotely. Users receive real-time alerts on their devices, ensuring they are informed of any unusual activities around their homes.

Moreover, the energy management aspect of Home Automation 1503 cannot be overlooked. The system promotes energy-saving practices by allowing users to schedule lighting, heating, and appliance operation, reducing overall consumption and contributing to a more sustainable lifestyle.

In conclusion, Home Automation 1503 represents a significant advancement in home technology, enhancing security, convenience, and energy efficiency. With its diverse range of features, compatibility with various devices, and user-focused design, it offers a glimpse into the future of smart living, making homes not just places to live, but intelligent ecosystems that cater to the comfort and safety of their inhabitants.