Home Automation 1503 Access the system from a lo- cal phone, Press Show to advance the display to

Page 70

Home Automation,

Press SHOW to advance the display to

HIGH SECURITY MODE.

In HIGH SECURITY MODE, the MAS- TER CODE is always required to do the following functions:

a.View or Change SET UP items. (SET-UP key)

b.Create PROGRAMS. (PROG key)

c.View or delete PROGRAMS or the EVENT LOG (SHOW key)

d.Access the system from a lo- cal phone.

With HIGH SECURITY MODE off, no code is required if the security system is in the OFF mode. If the security system is on (i.e. in the HOME, ASLEEP or AWAY mode) then you will be prompted to enter the mas- ter code when you press the SET-UP, PROG or SHOW keys.

If your system is set up with HIGH SECURITY on, the display will request the MASTER CODE whenever you select one of these functions, even if the security system is OFF. Simply enter your master code.

Your system was shipped from the factory with HIGH SECURITY off, which allows you to change set up items, create and delete programs and view the event log without having to enter your master code. In most residential applications, this is appropriate. If you have a commercial installation, or would like added protection from unautho- rized access to the system, you may wish to turn the HIGH SECURITY MODE on.

To turn HIGH SECURITY MODE ON, press a 1 then ENTER. To turn HIGH SECURITY

MODE OFF, press a 0 then press ENTER.

ENABLE AUTO-BYPASS

The AUTO-BYPASS feature allows the system to automatically bypass an open zone when the system is armed, rather than setting off the alarm. In some applications, it may be preferable to allow arming ONLY if all zones are secure.

To turn AUTO-BYPASS ON, press a 1 then ENTER. To turn AUTO-BYPASS OFF, press a 0 then press ENTER.

With AUTO-BYPASS OFF, all zones to be armed must be secure when the system is armed. Otherwise, the console will beep three times and display “ZONE NOT SECURE.” If the system is armed and a zone is open when the EXIT DELAY expires, the alarm will sound.

You have now seen all items in the CODES category. Pressing the SHOW key again will cause the dis- play to start over with the MASTER CODE. Press CANCEL to return to the SET-UP menu.

MISCELLANEOUS CATEGORY

To view or change items in the MISCELLANEOUS category, press SET-UP, 2.

To see the next item in this category, press SHOW. To see the previous item, press SET-UP. To exit the set-up facility, press CANCEL.

The first item in the MISCELLA- NEOUS category is the ENTRY DELAY.

68

Image 70
Contents HomeAutomation,Inc SECURITY-OFF, *, 2, ENTER, Code Alarm SystemCancel SECURITY-OFF, #, #, CodePage Contents Scrolling Through Names Show Programs Show ALL Programs Delete ProgramGoodbye Panic Button Over the Phone # # # # # # PC Access ALL OFF Status EventsSET-UP Model 1503 Default Settings Model 1503 LC Model NumberModel 1503 Version Serial NumberModel 1503 Version Model 1503-LC Differences Between Version 2 and LC ModelsDifferences in models are noted in this manual Things YOU should Know To silence the beeper, press the Cancel key For more information, seeTurning the Security System on Silencing AlarmsThat’s all there is to it Press the SECURITY-OFF keyExit Delay L E E PTo quick arm the system in the Away mode, press AWAY, Away Then enter your master code number Burglar Alarm Activated System now waits the Outside Siren Delay 60 seconds Mediately ALARM! Zone Name TrippedEmergency ALARM! Police EMG BTN Tripped Please Respond ImmediatelySpond Immediately Fire Alarm Fire EMG BTN TrippedMedical EMG BTN Tripped Alarm Reset Alarm Cancel Page Used is recorded in the event log Master CodeAuxiliary Codes Duress CodeModel 1503-LC cannot use Model 1102 Expansion Enclosures Module Types Appliance Modules113 House Code X+2House Code X+3 Console will beep, and a ALL OFFMomentary ON/OFF Commands Temperature this is the air temperature read by the Pesm Freeze Alarm Temperature Control Appliances Model 1102 Expansion Enclosure Model1503Version2only Temperatures lo and hi tem- peratures All Lights On, All Off Press the UNIT-NUMBER key Program StoragePress the Prog key Press 4 or the Show key 4 times, thenSince 600 PM is what we want, press Automatic Calculation of SUNRISE/ S U N S E TPress PROG, UNIT-NUMBER, 2, OFF Mmdd DAY Press Prog key if you aren’t already in the Program menu Press 9 for weekendsPress the Enter key If the display reads as above, pressSome other programming sugges- tions Press Cancel so that this program is not storedNow press *, Asleep Procedure for programming a button is Display will read GO to BED ALL OFF EnterDisplay will read Prog GO to BED Front Porch DIM Press Cancel twice to exit the Show Programs menu Display will read RUN GO to BED Enter CancelPress Show to see the second and third programs for Button Display will read GO to BED Master AsleepAppendix shows which buttons are activated for each zone Example Program Button 2 to run at 600 PM every weekdayPress TIME, 6, 0, 0, PM Press DATE-DAY, DATE-DAY, 8, Enter Display should read When Away ALL OFF Display should show When Z6 ALM Stairwell on forAppendix shows which buttons are activated by which zones LIT When Z1 ALM if DRK Unit 1 onDisplay Conditional DRKTime Clocks Light on178, Enter when away ALL OFF 178, Enter when away Unit 1 on Press PROG, *, 180, ENTER, UNIT-NUMBER, 1, ON, EnterPrograms for when security off DAYS, ENTER, Enter Press the Show key to see the next program in memory Show ProgramsPress the Show key Press the SET-UP key to go back toShow Programs for ALL Unit Numbers Previous program in memoryPulse and Tone Phones Remote Phones Phone Access Denied Remote Lockout Model 1503 will say Home Goodbye Star * Cancel RepeatMessage Model 1503 Version 2 only Control Enter Unit NUMBER, then Pound KEYUnit numbers 17 and 19 OFF Temperature is 76 DegreesMain Menu Control, then press the # keyModel 1503 will then confirm the new low setting ASLEEP, 3 AWAY, Star * CAN- CELYou will then be returned to the main menu ExamplesModel 1503 will say Button Enter your code numberHad Trouble Fire Zone in ALARM, Trouble NOW or had TroubleZone X Zone Type Bypassed To hear the event log, press 7 from the main menuGoodbye Record MESSAGE, 8 Repeat Message Play ADDRESS, Star CancelTo Cancel from the message menu, press Panic Button Over the Phone # # #PC Access Model 1503 Voice DIAL-OUT Planner Fire Alarm Dial OrderFreeze Alarm Dial Order Dial OUT 1 onHome Phone Emergency Numbers Fire Police MedicalOther instructions Code againDigital Dialer To turn all lights off, press SET Time SET DateRemember Your NEW Code To set up your CODES, press SET-UP, 1CodesDisplay will request your Through 7 for SundayThere are 4 auxiliary codes Auxiliary Code ENTER. To remove a code, enter 0000 in its placePress Show to advance the display to Access the system from a lo- cal phoneMode OFF, press a 0 then press Enter Exit Delay Number HouseHouse Code Default setting for ENTRY/ Exit Chime is YES Default setting for Quick ARM Enabled is no Default setting for Answer Outside CALL? is YES Default setting for TELE- Phone Access is onTo exit the set-up facility, press Default dial type is Tone Default for Remote Commands OK? is YESFactory default for Rings Before Answer is Dial TypePhone numbers can be up to 16 digits Dial OUT 1 on Dial OUT 1 OFFSame as Dial OUT Number Dial OUT Number Dial OUT 2 on Dial OUT 2 OFFDial OUT Number Dial OUT 3 on Dial OUT 3 OFF Dial OUT Number Dial OUT 4 on Dial OUT 4 OFFInstaller Name Number Do not return to a burning houseFederal Communications COMMIS- Sion Notice Canadian Department of COMMUNI- Cations Notice

1503 specifications

Home Automation 1503 is a state-of-the-art system designed to elevate the standards of modern living by integrating advanced technology into everyday activities within the home. This comprehensive solution seamlessly connects various household devices, allowing users to control them through a central interface, typically accessible via smartphones, tablets, or dedicated control panels.

One of the hallmark features of Home Automation 1503 is its interoperability. The system is compatible with a wide array of devices, ranging from lighting and HVAC systems to security cameras and smart appliances. This ensures that homeowners can create a cohesive and interconnected environment tailored to their specific needs.

The technologies underpinning Home Automation 1503 include wireless communication protocols such as Wi-Fi, Zigbee, and Z-Wave. These protocols facilitate reliable communication between devices, ensuring that commands are transmitted quickly and accurately. Additionally, the system employs AI and machine learning algorithms to create smart environments that adapt to user preferences, enhancing convenience and energy efficiency.

Another significant characteristic of Home Automation 1503 is its user-friendly interface. The system often features customizable dashboards, enabling users to monitor and manage their home from a single screen. Voice control capabilities, integrated with popular virtual assistants such as Amazon Alexa or Google Assistant, allow for hands-free operation, making everyday tasks even more convenient.

Security is a top priority in Home Automation 1503. The system supports advanced security features like smart locks, motion sensors, and video surveillance, all of which can be monitored remotely. Users receive real-time alerts on their devices, ensuring they are informed of any unusual activities around their homes.

Moreover, the energy management aspect of Home Automation 1503 cannot be overlooked. The system promotes energy-saving practices by allowing users to schedule lighting, heating, and appliance operation, reducing overall consumption and contributing to a more sustainable lifestyle.

In conclusion, Home Automation 1503 represents a significant advancement in home technology, enhancing security, convenience, and energy efficiency. With its diverse range of features, compatibility with various devices, and user-focused design, it offers a glimpse into the future of smart living, making homes not just places to live, but intelligent ecosystems that cater to the comfort and safety of their inhabitants.