INITIAL SETTING
CAMERA ADDRESS SETUP
Dip Switch setting is same as the following example:
EX) CAMERA ADDR: When it's number 1, set as follows.
1 2 3 4 5 6 7 8
ON
OFF
SW500
Setting communication Protocol
Use number 5~8 PIN of SW501 to set communication Protocol.
PIN | PIN5 | PIN6 | PIN7 | PIN8 |
Comp | ||||
A | OFF | OFF | OFF | OFF |
B | ON | OFF | OFF | OFF |
C | OFF | ON | OFF | OFF |
|
|
|
|
|
D | ON | ON | OFF | OFF |
E | OFF | OFF | ON | OFF |
F | ON | OFF | ON | OFF |
|
|
|
|
|
G | OFF | ON | ON | OFF |
H | ON | ON | ON | OFF |
I | OFF | OFF | OFF | ON |
|
|
|
|
|
J | ON | OFF | OFF | ON |
K | OFF | ON | OFF | ON |
L | ON | ON | OFF | ON |
|
|
|
|
|
M | OFF | OFF | ON | ON |
N | ON | OFF | ON | ON |
O | OFF | ON | ON | ON |
|
|
|
|
|
P | ON | ON | ON | ON |
A :
B :
SEE INSTRUCTION MANUAL
SW500
SW501
(BOTTOM VIEW)
Baud Rate Setting
Use PIN 3 and 4 of SW501.
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
ON |
|
|
|
|
|
|
|
OFF |
|
|
|
|
|
|
|
|
|
| SW | 501 |
|
|
|
BAUD RATE | PIN 3 | PIN 4 |
4800 BPS | ON | ON |
9600 BPS | OFF | ON |
|
|
|
19200 BPS | ON | OFF |
38400 BPS | OFF | OFF |