Samsung SCC-643P manual Alarm SET, Alarm Priority SET, Alarm in SET

Page 48

PATTERN can be set upto 3. Choose 1, 2, or 3 with the left or right key in the "PATTERN SET" and press [ENTER] to get into the PATTERN set up screen. From the moment "PATTERN 1 SET" is gone for 30 seconds, it memorizes the MANUAL movements and after 30 seconds it will return to a higher menu. If you want to finish set up before the 30-second ends, press [ENTER].

5. ALARM SET

It consists of 4 ALARM INPUTs and 3 ALARM OUTs.It can sense an ALARM input from exterior SENSORs and it performs with PRESET or PATTERN function and outputs the ALARM OUT signals.

It recognizes the ALARM signal input as an ALARM signal when it continues more than 150ms for a time and each ALARM movement time is decided depending on it's correspondence to the DWELL TIME of the PRESET and PATTERN connected.

* * MAIN MENU * *

CAMERA...

VIDEO SET...

PRESET...

AUTO MODE...

ALARM SET...

OTHER SET...

Press

[Enter]

( ALARM SET)

ALARM PRIORITY SET.. ALARM IN SET.. ALARM OUT SET.. ALARM PATTERN SET.. AUX OUT CONTROL..

RET

ALARM PRIORITY SET

This sets the priority of the 4 ALARM inputs so ALARM can work corresponding to the priority. The priority of the DEFAULT is ALARM1: 1, ALARM2: 2, ALARM3: 3, ALARM4: 4, MOTION: 5. If the ALARM is working at the same time and the priority is the same, it will operate according to the DEFAULT priority. While the ALARM is working, it cannot detect MOTION.

ALARM IN SET

This sets the input TYPE to "NO" (Normal Open), "NC" (Normal Close), or "OFF" depending on the features of the SENSOR connected.

ALARM PRIORITY

ALARM1 1

ALARM2 2

ALARM3 3

ALARM4 4

EXITQUIT

ALARM IN

ALARM1 NO

ALARM2 NC

ALARM3 NO

ALARM4 NC

EXITQUIT

3-20

Image 48
Contents SCC -643P Safety Precautions Page Before Usage Approval of Standards Table of contents Appendix Product specifications Chapter SCC-643 P Overvie w SCC-643P Introduction Locations of Control Back Adapter Connection Initial Setting Camera Address SetupSetting RS-422A/RS-485 termination Switch Setting 100 117 177 237 Chapter CC-643P Installatio n Before Installing Preparing the Cables Cable Connection Installing SCC-643P Indoor Housing SHG-120 Ceiling Mount Adaptor SADT-100CM Installing the Camera Assemble the COVER-DOME onto the Dome Setup Menu Overvie w Structure of the Setup Menu Alarm SET Alarm Priority SET Camera SET Menu Camera IDSync COLOR/BW Zoom Speed Motion DETVideo SET Menu ExitIris ALC BLC Submenu of the ALC menuManu ShutterAGC Slow NormalFast White BAL White BAL Manu Special OFF Auto Focus Oneaf Zoom Exit Quit Special Auto Focus ZoomPreset Preset 2 ALARM2, Preset 3 ALARM3, PresetPreset ID Position SETVideo SET ScanAuto Mode Auto PANStart SET END SETDirection EndlessSpeed PatternAlarm SET Alarm Priority SETAlarm in SET Alarm OUT Alarm PatternAUX OUT Control SET UP Time for Home Return Other SETHome Return Home PositionPrivacy Zone PAN/TILTCAM Reset Product specifications SCC-643P