Setting the On/Off timer

You can set the air conditioner to turn on/off automatically at desired time.

Setting On timer while the air conditioner is off / Off timer while the air conditioner is on.

Lighting

<Setting On timer>

Lighting

1. Press the On timer or Off timer button.

ffOn/Off timer indicator will blink on the remote controller display.

2. Press the On timer or Off timer button repeatedly to set the time.

ffYou can set the time in half hourly units from 30 minute ~ 3 hours and hourly units from 3 hour ~ 24 hours.

ffThe set hour is set to minimum 30 minutes and maximum 24 hours.

3. Press the Set/Cancel button to activate it.

ffOn/Off timer indicator will stop blinking and the set time will be displayed.

ff icon appears in the display of the indoor unit and timer setting will be completed.

fIfyou don't press the Set/Cancel button within 10 seconds after selecting the On/ Off timer function, the air conditioner will return to the previous status, so you should check the On/Off timer indicator on the remote controller display or icon on the indoor unit display.

Cancel Press the Set/Cancel button once again.

Additional options available in On timer mode

You can select from Auto Cool Dry Purity Heat.

When setting the on timer with Heat mode, the air conditioner will operate with Auto mode.

You can adjust the temperature in Auto/Dry mode. Operation mode will change to Cool mode if you press the Temp + or - button in Auto mode, and you cannot adjust the temperature during Purity mode.

You cannot adjust the fan speed.

ENGLISH

 

• Only the latest setting timer will be applied between the On Timer/Off Timer

NOTE

and good'sleep functions.

• About 10 seconds after setting the On timer, only the On timer indicator will appear on the remote controller display.

• If you press the Powerbutton on the indoor unit after setting the On timer function with the remote controller, Timer indicator on the indoor unit display

<Setting Off timer>

will disappear and the function will be canceled. However, Timer indicator on

the remote controller will remain on but the function will not work.

 

23

사우디,인도,나이지리아향 FAC MEMORY 냉방_IBIM_EN_03794A(7).indd 23

2014-03-12 오전 10:29:51

Image 24
Contents Questions or COMMENTS? This product is RoHS compliantAir Conditioner Thank you for purchasing this Samsung productFeatures of your new air conditioner Seasons of effective cleaningSmart sensor Applicable to Affvsd onlyContents Safety precautions Injury or property damageFfThis may result in electric shock or fire For Power Supply Warning For Using Do not place objects or devices under the indoor unit For Cleaning Do not clean the inside of the air conditioner by yourself Using indoor unit Using outdoor unitInstalling outdoor unit Checking before useAuxiliary power switch Auxiliary power switch NFB, ELB, etcOperation ranges Functions available for each modelChecking the name of the parts Indoor unitDisplay Buttons on control panelConditioner will operate with auto mode Operation with control panelFan speed of each air outlet will differ Checking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic operation AutoCool DryPress the button to adjust the desired temperature Except in Auto modePress the button to turn on the air conditioner Solomode RemarksPress the button on the remote controller in the Cool mode Turbo function is only available in the Cool modeTurbo operation Air flow directionWhen the air conditioner is on and in cool mode Goodsleep operationTemperature and fan speed changes in goodsleep mode Setting the On/Off timer Goodsleep functionsYour air conditioner will turn on Air conditioner will turn on after 3 hoursPress the button during Cool mode To adjust the lighting level of an indoor unitSmart sensor operation Lighting functionAuto clean operation Quiet operationCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Product can be scratched easilyCleaning the Full HD filter Remove dust with a vacuum cleaner or running waterFull HD filter filters the big dust of incoming air Pull out the Full HD filter in the arrow directionCleaning the Zero filter Troubleshooting Conditioner is Odors permeateHeard when refrigerant flow movement changes. It is normal Water isOpen Source Announcement Installation parts English Required tools General toolsTools for test operations Choosing the installation location Outdoor unitIndoor/outdoor unit installation diagram Installation space for floor type indoor unitPiping length for indoor/outdoor unit installation Fixing outdoor unit Outdoor unitAccessories Indoor unit accessoriesOutdoor unit accessories Installation accessoriesConnecting pipes Installation procedureDrilling a hole and fixing the indoor unit FfDrill a hole with diameter of 60~65mm towards the outsideFfFlare process FfFlare lengthFfIncorrectly flared pipes FfTightening of connection parts FfPipe insulationIndoor Use finishing tape wind up the refrigerant pipe Connecting drain hose Connection with wire-concealed pipingFix the drain hose tightly to prevent any water leakage Wiring standard Connecting procedureElectrical work Safety information on outdoor unit power supply Type of outdoor unit power supplyHow to connect your extended power cables FfItems to prepareCable Apply heat to the contraction tube to contract it Vacuum pump Vacuuming pipePerforming leak test Test part for indoor unitTest part for outdoor unit Nm = 10 kgfcmInstalling the earth wire Charging refrigerantCharge the refrigerant depending on the pipe length Display the temperature of indoor heat exchanger Check and test operationDisconnect the pipe Memo