Samsung AF28FVZDAWKNMG, AF28FVSDADFNMG manual For Using

Page 8

FOR USING

WARNING

If the appliance is flooded, please contact your nearest service center. ffFailing to do so may result in electric shock or fire.

If the appliance generates a strange noise, a burning smell or smoke, cut-off the power supply immediately and contact the nearest service center.

ffFailing to do so may result in electric shock or fire.

In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching the power line. Do not touch the appliance or power line.

ffDo not use a ventilating fan.

ffA spark may result in an explosion or fire.

To reinstall the air conditioner, please contact your nearest service center. ffFailing to do so may result in problems with the product, water leakage, electric

shock, or fire.

ffA delivery service for the product is not provided. If you reinstall the product in another location, additional construction expenses and an installation fee will be charged.

ffEspecially, when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air, please contact your nearest service center.

Do not operate the appliance with wet hands.

 

ffThis may result in electric shock.

 

Do not strike or pull the air conditioner with excessive force.

 

ffThis may result in fire, injury, or problems with the product.

 

ffImportantly, if the support bracket is excessively impacted, it may become

 

damaged.

 

Do not place an object near the outdoor unit that allows children to climb onto

 

the machine.

 

ffThis may result in children seriously injuring themselves.

 

Do not turn the air conditioner off with the circuit breaker while it is operating.

 

ffTurning the air conditioner off and then on again with the circuit breaker may

 

cause a spark and result in electric shock or fire.

 

After unpacking the air conditioner, keep all packaging materials well out of the

 

reach of children, as packaging materials can be dangerous to children.

 

fIfa child places a bag over its head, it may result in suffocation.

 

Do not insert your fingers or foreign substances into the outlet when the air

 

conditioner is operating or the front panel is closing.

 

ffTake special care that children do not injure themselves by inserting their fingers

 

into the product.

7

ENGLISH

사우디,인도,나이지리아향 FAC MEMORY 냉방_IBIM_EN_03794A(7).indd 7

2014-03-12 오전 10:29:44

Image 8 Contents
Questions or COMMENTS? This product is RoHS compliantAir Conditioner Thank you for purchasing this Samsung productFeatures of your new air conditioner Seasons of effective cleaningSmart sensor Applicable to Affvsd onlyContents Safety precautions Injury or property damageFfThis may result in electric shock or fire For Power Supply Warning For Using Do not place objects or devices under the indoor unit For Cleaning Do not clean the inside of the air conditioner by yourself Using indoor unit Using outdoor unitInstalling outdoor unit Checking before useAuxiliary power switch Auxiliary power switch NFB, ELB, etcOperation ranges Functions available for each modelChecking the name of the parts Indoor unitDisplay Buttons on control panelFan speed of each air outlet will differ Conditioner will operate with auto modeOperation with control panel Checking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic operation AutoCool DryPress the button to adjust the desired temperature Except in Auto modePress the button to turn on the air conditioner Solomode RemarksPress the button on the remote controller in the Cool mode Turbo function is only available in the Cool modeTurbo operation Air flow directionWhen the air conditioner is on and in cool mode Goodsleep operationTemperature and fan speed changes in goodsleep mode Setting the On/Off timer Goodsleep functionsYour air conditioner will turn on Air conditioner will turn on after 3 hoursPress the button during Cool mode To adjust the lighting level of an indoor unitSmart sensor operation Lighting functionAuto clean operation Quiet operationCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Product can be scratched easilyCleaning the Full HD filter Remove dust with a vacuum cleaner or running waterFull HD filter filters the big dust of incoming air Pull out the Full HD filter in the arrow directionCleaning the Zero filter Troubleshooting Conditioner is Odors permeateHeard when refrigerant flow movement changes. It is normal Water isOpen Source Announcement Installation parts English Tools for test operations Required toolsGeneral tools Choosing the installation location Outdoor unitPiping length for indoor/outdoor unit installation Indoor/outdoor unit installation diagramInstallation space for floor type indoor unit Fixing outdoor unit Outdoor unitAccessories Indoor unit accessoriesOutdoor unit accessories Installation accessoriesConnecting pipes Installation procedureDrilling a hole and fixing the indoor unit FfDrill a hole with diameter of 60~65mm towards the outsideFfIncorrectly flared pipes FfFlare processFfFlare length Indoor Use finishing tape wind up the refrigerant pipe FfTightening of connection partsFfPipe insulation Fix the drain hose tightly to prevent any water leakage Connecting drain hoseConnection with wire-concealed piping Electrical work Wiring standardConnecting procedure Safety information on outdoor unit power supply Type of outdoor unit power supplyCable How to connect your extended power cablesFfItems to prepare Apply heat to the contraction tube to contract it Vacuum pump Vacuuming pipePerforming leak test Test part for indoor unitTest part for outdoor unit Nm = 10 kgfcmCharge the refrigerant depending on the pipe length Installing the earth wireCharging refrigerant Disconnect the pipe Display the temperature of indoor heat exchangerCheck and test operation Memo
Related manuals