Samsung AF28FVZDAWKNMG, AF28FVSDADFNMG manual Choosing the installation location, Outdoor unit

Page 38

Choosing the installation location

Indoor unit

ffInstall the unit at a place close to the wall facing the outside as it is necessary to perform piing connection with the outdoor unit.

-- It is effective to install the unit at the place where air flow is not blocked and the cool air can be distributed throughout the room.

ffInstall the unit at a place where there is no obstacle against the wind around the air intake and air outlet. ffAvoid a place near the door which is frequently used by people.

ffAvoid a place exposed to direct sunlight. (If it is unavoidable, install a sunshade). -- Surface of the product may get discolored.

❋❋Install it on even ground.

Make sure there is no abnormal operation or noise generation.

If installed on uneven ground, water may overflow.

Outdoor unit

ffAvoid a place exposed to direct sunlight. (If it is unavoidable, install a sunshade). ffA place free from the risk of combustible gas leakage.

ffA place which can bear the weight of the unit.

ffA place which can bear the fixing strength of the outdoor unit. ffAvoid a place exposed to oil (including machine oil) ffAvoid a saline place.

ffAvoid a place exposed to sulfide gas (hot spring zone).

-- When installing the unit at such special environmental conditions, it may cause trouble to the product. When it is unavoidable, special maintenance is required.

ffA place where discharged air and noise of the outdoor unit does not disturb the neighborhood.

-- Take extra care not to cause any inconvenience to your neighbors when installing the unit on the borderline with your neighborhood.

ffA place where strong wind does not head against the air outlet of the outdoor unit.

-- If a strong wind heads directly against the air outlet at the time of cool operation, a safety device can be operated.

❋❋Do not install the outdoor unit on a unstable places (such as rooftop). If installation is unavoidable, make sure that you fixed the unit firmly. Avoid places where strong wind or storm can possibly knock down the product (such as seashore or place with frequent storm)

ENGLISH

37

사우디,인도,나이지리아향 FAC MEMORY 냉방_IBIM_EN_03794A(7).indd 37

2014-03-12 오전 10:29:56

Image 38
Contents Questions or COMMENTS? This product is RoHS compliantAir Conditioner Thank you for purchasing this Samsung productSmart sensor Features of your new air conditionerSeasons of effective cleaning Applicable to Affvsd onlyContents Safety precautions Injury or property damageFfThis may result in electric shock or fire For Power Supply Warning For Using Do not place objects or devices under the indoor unit For Cleaning Do not clean the inside of the air conditioner by yourself Installing outdoor unit Using indoor unitUsing outdoor unit Checking before useOperation ranges Auxiliary power switchAuxiliary power switch NFB, ELB, etc Functions available for each modelChecking the name of the parts Indoor unitDisplay Buttons on control panelFan speed of each air outlet will differ Conditioner will operate with auto modeOperation with control panel Checking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesCool Basic operationAuto DryPress the button to turn on the air conditioner Press the button to adjust the desired temperatureExcept in Auto mode Solomode RemarksTurbo operation Press the button on the remote controller in the Cool modeTurbo function is only available in the Cool mode Air flow directionWhen the air conditioner is on and in cool mode Goodsleep operationTemperature and fan speed changes in goodsleep mode Setting the On/Off timer Goodsleep functionsYour air conditioner will turn on Air conditioner will turn on after 3 hoursSmart sensor operation Press the button during Cool modeTo adjust the lighting level of an indoor unit Lighting functionAuto clean operation Quiet operationCleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Product can be scratched easilyFull HD filter filters the big dust of incoming air Cleaning the Full HD filterRemove dust with a vacuum cleaner or running water Pull out the Full HD filter in the arrow directionCleaning the Zero filter Troubleshooting Conditioner is Odors permeateHeard when refrigerant flow movement changes. It is normal Water isOpen Source Announcement Installation parts English Tools for test operations Required toolsGeneral tools Choosing the installation location Outdoor unitPiping length for indoor/outdoor unit installation Indoor/outdoor unit installation diagramInstallation space for floor type indoor unit Fixing outdoor unit Outdoor unitOutdoor unit accessories AccessoriesIndoor unit accessories Installation accessoriesDrilling a hole and fixing the indoor unit Connecting pipesInstallation procedure FfDrill a hole with diameter of 60~65mm towards the outsideFfIncorrectly flared pipes FfFlare processFfFlare length Indoor Use finishing tape wind up the refrigerant pipe FfTightening of connection partsFfPipe insulation Fix the drain hose tightly to prevent any water leakage Connecting drain hoseConnection with wire-concealed piping Electrical work Wiring standardConnecting procedure Safety information on outdoor unit power supply Type of outdoor unit power supplyCable How to connect your extended power cablesFfItems to prepare Apply heat to the contraction tube to contract it Vacuum pump Vacuuming pipeTest part for outdoor unit Performing leak testTest part for indoor unit Nm = 10 kgfcmCharge the refrigerant depending on the pipe length Installing the earth wireCharging refrigerant Disconnect the pipe Display the temperature of indoor heat exchangerCheck and test operation Memo
Related manuals
Manual 52 pages 26.44 Kb