Samsung AR18JQFSBWKNMG, AR12JQFNBWK/MG manual Mode, English-20, Additional options available

Page 20

mode

For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep Sound sleep Wake up stage.. When the air conditioner is operating in Cool/Heat (ARJQ) mode;

1.

Press the Timer button..

 

2.

Press the

button until (

) indicator starts to blink..

3.

Press the SET button to set the

mode..

 

-- ( ) indicator will keep blinking and you can set the time..

4.Press the button to set the time..

-- You can set the time in half hour unit from 30 minutes (0..5 on the display) ~ 3 hours and hour unit from 3~12 hours..

-- Time can be set from minimum 30 minutes to maximum 12 hours..

 

-- Default time setting for the

mode is 8 hours..

 

 

5. Press the SET button to complete the

mode setting..

 

 

-- (

) indicator and the set time of the

mode will be displayed on

 

the remote controller display..

 

 

 

-- Timer indicator (

) will be displayed on the indoor unit display..

 

 

--

mode setting will be cancelled if you don't press the SET button within

 

10 seconds after setting the time.. Therefore, check for the ( ) indicator on the

 

 

 

 

remote controller display and the Timer indicator ( ) on the indoor unit display..

 

Cancel

ffPress the

button to make the set time to display as

,

 

 

and press the SET button..

 

 

Remote controller display

 

 

 

 

 

 

 

 

 

 

 

Additional options available in

mode

 

You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.

Fan speed will be adjusted automatically according to themode.

However, If you selectmode while heating operation is on, you can adjust fan speed.

When themode is on.

In Cool mode: Air flow direction will be adjusted automatically.

In Heat (ARJQ) mode: Adjusting air flow direction is available.

Temperature and fan speed change inmode

•• Fall asleep: Eases you into sleep by dropping the temperature..

•• Sound sleep: Relaxes your body and raises your temperature slightly..

•• Wake up: Allows you to wake up from comfortable intermittent air and it makes you feel refreshed..

Recommended set temperature is between 25 °C ~ 27 °C for cooling and 21 ˚C~23 ˚C for heating.

• If the set temperature is too low, you may feel cold during sleep or catch a cold..

Optimal operation hour of mode is 8 hours.. Therefore, if the time is set too short or long, you may not feel as comfortable as you would expect..

If the mode is set over 5 hours, Wake up stage will begin when 1 hour is remaining in the operation time and the air conditioner will stop automatically..

When the On timer and the function is set simultaneously, the air conditioner will only apply the function that was set later..

English-20

MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-04540A.indd 20

9/1/2014 5:10:32 PM

Image 20
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges Technical Specifications English-11Checking the name of the parts Main partsDisplay English-12English-13 Checking the remote controllerRemote controller buttons Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Adjusting the air flow direction Vertical air flowHorizontal air flow English-17Setting the On/Off timer Setting the On timerPress the SET button FfPress the Power button English-18Setting the Off timer English-19Additional options available ModeEnglish-20 Step cooling function English-21English-22 Using the Fast functionUsing the Comfort function English-23 Using the Single User functionPress the Single user button on the remote controller Using the Auto Clean function Setting the Beep soundLighting in Auto clean mode English-24Cleaning the air conditioner Cleaning the outdoor unit heat exchangerEnglish-25 Heat exchangerCleaning the air filter Removing the Air filterEnglish-26 Remove the air filter from the main bodyTop of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-27 Maintaining the air conditioner English-28Troubleshooting Air conditionerEnglish-29 Take the cover off and takeError is indicated Press the PowerOdors permeate Water is dropping07stIn llan atio General informationEnglish-31 Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitEnglish-33 Where sulfide gas existsOutdoor Unit When installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-34  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-35Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsAssembling the hanger screw English-37This QR code for detail video of indoor unit installation Removing the screwsRemoving the Cover panel Before mounting the indoor unit English-38Assembling the Cover panel After mounting the indoor unit English-39Connecting the assembly cable Cable specificationConnecting the cable English-40English-41 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number English-42 Smooth the cut edgesCut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-43 Unscrew the caps at the end of each pipeCracked English-44Correct Inclined Drain hose installation English-45Change the direction only when it is necessary English-46Shield Downwards as seen in the pictureEvacuating the connected pipes English-47Connect a drain hose to the drain plug Drain hole Drain plugOuter Torque Adding RefrigerantEnglish-48 1975 English-49Please fill in with indelible ink Performing the gas leak tests English-50English-51 Outdoor unit installed on the wall by rackFixing the outdoor unit in place Smart Install mode English-52English-53 Off / Blinking / OnFinal check and trial operation English-54Packing and unpacking guide English-55How to connect your extended power cables English-56Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-57 Questions or COMMENTS? 0211