Samsung AR24JQFSBWKNMG manual Fixing the installation plate, Optional accessories, English-36

Page 36

• The flare nuts are attached to the end of each pipe of an evaporator or a service port.

Use the nuts when connecting the pipes.

The wire assembly cable is optional. If it is not supplied, use the standard cable.

The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below.

Optional accessories

The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.

Insulated Assembly Pipe,

Insulated Assembly Pipe,

Insulated Assembly Pipe,

PE T3 Foam Tube

Vinyl Tapes (2)

Drain Hose,

Ø6.35 mm x 5 m (1) ✴✴12/18✴✴

Ø12.70 mm x 5 m (1)

Ø15.88 mm x 4 m (1)

Insulation (1)

length 2 m (1)

Ø6.35 mm x 4 m (1) ✴✴24✴✴

✴✴12/18✴✴

✴✴24✴✴

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Putty 100 g (1)

Pipe Clamps A (3)

Pipe Clamps B (3)

Cement Nails (6)

M4 x 25 Tapped

Screws (6)

4-wire

Assembly Cable (1) ✴✴12/18/24✴✴

• If these accessories are supplied, they will be in the accessory box.

Tools required for installation

General Tools

• Vacuum Pump(Backward flowing prevention)

• Manifold Gauge

• Stud Finder

• Torque Wrench

• Pipe Cutter

• Reamer

• Pipe Bender

• Spirit Level

• Screw Driver

• Spanner

• Drill

• L Wrench

• Measuring Tape

Tools for test operations

 

 

 

• Thermometer

• Resistance Meter

 

• Electroscope

 

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

Direction of pipe

 

 

 

• Left (B)

 

 

• Underside_right (C)

A

B

• Rear_right or left (D)

D

D

 

C

 

You can install the refrigerant pipe in the left/right/bottom, or the rear side of the indoor unit.

• If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

English-36

MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-04540A.indd 36

9/1/2014 5:11:04 PM

Image 36
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Checking before use Operation rangesEnglish-10 Technical Specifications English-11Checking the name of the parts Main partsDisplay English-12Checking the remote controller Remote controller buttonsEnglish-13 Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Adjusting the air flow direction Vertical air flowHorizontal air flow English-17Setting the On/Off timer Setting the On timerPress the SET button FfPress the Power button English-18Setting the Off timer English-19Mode English-20Additional options available Step cooling function English-21Using the Fast function Using the Comfort functionEnglish-22 Using the Single User function Press the Single user button on the remote controllerEnglish-23 Using the Auto Clean function Setting the Beep soundLighting in Auto clean mode English-24Cleaning the air conditioner Cleaning the outdoor unit heat exchangerEnglish-25 Heat exchangerCleaning the air filter Removing the Air filterEnglish-26 Remove the air filter from the main bodyReassembling the Air filter English-27Top of the Air filter into the main body.. ➀ Maintaining the air conditioner English-28Troubleshooting Air conditionerEnglish-29 Take the cover off and takeError is indicated Press the PowerOdors permeate Water is droppingGeneral information English-3107stIn llan atio Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unit Where sulfide gas exists Outdoor Unit English-33 When installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-34  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-35Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsAssembling the hanger screw English-37This QR code for detail video of indoor unit installation Removing the screwsRemoving the Cover panel Before mounting the indoor unit English-38Assembling the Cover panel After mounting the indoor unit English-39Connecting the assembly cable Cable specificationConnecting the cable English-40Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-41 English-42 Smooth the cut edgesCut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-43 Unscrew the caps at the end of each pipeEnglish-44 Correct InclinedCracked Drain hose installation English-45Change the direction only when it is necessary English-46Shield Downwards as seen in the pictureEvacuating the connected pipes English-47Connect a drain hose to the drain plug Drain hole Drain plugAdding Refrigerant English-48Outer Torque English-49 Please fill in with indelible ink1975 Performing the gas leak tests English-50Outdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-51 Smart Install mode English-52English-53 Off / Blinking / OnFinal check and trial operation English-54Packing and unpacking guide English-55How to connect your extended power cables English-56Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-57 Questions or COMMENTS? 0211