Samsung AR12JQFNBWK/MG, AR24JQFNBWKNMG manual Fixing the outdoor unit in place, English-51

Page 51

Fixing the indoor unit in place

Perform the following work on the area where gas leak test was done priory.

After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate.

1.To minimise condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes.

2.Wind the pipe, assembly cable and drain hose with vinyl tape.

3.Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit.

4.Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place.

• Make sure pipe does not move when you install the indoor unit on an installation plate.

5.Wrap the rest of the pipe with vinyl tape.

6.Attach the pipe to the wall using clamps (optional).

Insulation

Pipes

 

Installation

 

plate

Connecting

Vinyl tape

pipes

Connecting wires

 

Drain hose

 

07stIn llan atio

Fixing the outdoor unit in place

Install the outdoor unit in level on a stable base to help avoid the generation of noise and vibration, especially when installing the unit close to a neighbor.

If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an appropriate support (wall or ground).

1.Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly.

2.Fix the outdoor unit in level to an appropriate support using anchor bolts.

3.If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly.

• Secure the rubber leg to help prevent the generation of noise and vibration.

'X' mm

'Y' mm

 

 

Rubber leg

 

Model

X

Y

12JR

507

292

12JQ

602

310

18/24JR

660

340

18JQ

 

 

24JQ

645

340

Outdoor unit installed on the wall by rack

Ensure the wall will be able to suspend the weight of rack and outdoor unit;

Install the rack close to the column as much as possible;

Install proper grommet in order to help reduce noise and residual vibration transferred by outdoor unit towards wall.

Designed to cut off residual vibration from outdoor unit to rack.

(not supplied with product)

Soft rubber designed to cut off vibration from rack to wall. (not supplied with product)

English-51

MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-04540A.indd 51

9/1/2014 5:12:10 PM

Image 51
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningChecking before use Operation rangesEnglish-10 English-11 Technical SpecificationsEnglish-12 Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsEnglish-13 Inserting the batteries Remote controller displayLow Battery warning Storing the remote controllerBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 English-17 Adjusting the air flow directionVertical air flow Horizontal air flowEnglish-18 Setting the On/Off timerSetting the On timer Press the SET button FfPress the Power buttonEnglish-19 Setting the Off timerMode English-20Additional options available English-21 Step cooling functionUsing the Fast function Using the Comfort functionEnglish-22 Using the Single User function Press the Single user button on the remote controllerEnglish-23 English-24 Using the Auto Clean functionSetting the Beep sound Lighting in Auto clean modeHeat exchanger Cleaning the air conditionerCleaning the outdoor unit heat exchanger English-25Remove the air filter from the main body Cleaning the air filterRemoving the Air filter English-26Reassembling the Air filter English-27Top of the Air filter into the main body.. ➀ English-28 Maintaining the air conditionerTake the cover off and take TroubleshootingAir conditioner English-29Water is dropping Error is indicatedPress the Power Odors permeateGeneral information English-3107stIn llan atio Indoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerWhere sulfide gas exists Outdoor UnitEnglish-33  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-34English-35 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseTools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsEnglish-37 Assembling the hanger screwEnglish-38 This QR code for detail video of indoor unit installationRemoving the screws Removing the Cover panel Before mounting the indoor unitEnglish-39 Assembling the Cover panel After mounting the indoor unitEnglish-40 Connecting the assembly cableCable specification Connecting the cableExtend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-41 Torque English-42Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-43English-44 Correct InclinedCracked English-45 Drain hose installationDownwards as seen in the picture Change the direction only when it is necessaryEnglish-46 ShieldDrain hole Drain plug Evacuating the connected pipesEnglish-47 Connect a drain hose to the drain plugAdding Refrigerant English-48Outer Torque English-49 Please fill in with indelible ink1975 English-50 Performing the gas leak testsOutdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-51 English-52 Smart Install modeOff / Blinking / On English-53English-54 Final check and trial operationEnglish-55 Packing and unpacking guideAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-56 Apply heat to the contraction tube to contract itEnglish-57 0211 Questions or COMMENTS?