Samsung AR18JRFNBWKXMG, AR12JQFNBWK/MG, AR24JQFNBWKNMG Maintaining the air conditioner, English-28

Page 28

Maintaining the air conditioner

If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.

1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut-off the power supply. There may be internal damage if moisture is left in components.

2.Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness.

Periodical checks

Refer to the following chart to maintain the air conditioner properly.

Type

Description

Every 2

Every 3

Every 4

Once a year

weeks

months

months

 

 

 

 

 

 

 

 

 

 

Clean the Full HD filter (1)

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

 

 

Indoor

Thoroughly clean the heat exchanger (2)

 

 

 

unit

Clean the cross fan (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pipe (2)

 

 

 

 

 

 

 

 

 

 

Replace the remote controller batteries (1)

 

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the outside of the unit (2)

 

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the inside of the unit (2)

 

 

 

 

 

 

 

 

 

 

Clean the electric components with jets of air (2)

 

 

 

Outdoor

 

 

 

 

 

Verify that all the electric components are firmly

 

 

 

unit

tightened (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean the fan (2)

 

 

 

 

 

 

 

 

 

 

Verify that all the fan assembly is firmly tightened (2)

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

 

 

: This check mark requires checking the indoor/outdoor unit periodically. Follow the description to maintain the air conditioner properly.

 

 

 

(1)

The described operations should be performed more frequently if

 

 

 

 

 

 

the area of installation is very dusty.

CAUTION

 

 

(2)

These operations must always be performed by qualified personnel.

 

 

 

 

 

For more detailed information, see the installation part in the

 

 

 

 

manual.

English-28

MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-04540A.indd 28

9/1/2014 5:10:54 PM

Image 28
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Operation ranges Checking before useEnglish-10 Technical Specifications English-11Checking the name of the parts Main partsDisplay English-12Remote controller buttons Checking the remote controllerEnglish-13 Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-16 Adjusting the air flow direction Vertical air flowHorizontal air flow English-17Setting the On/Off timer Setting the On timerPress the SET button FfPress the Power button English-18Setting the Off timer English-19English-20 ModeAdditional options available Step cooling function English-21Using the Comfort function Using the Fast functionEnglish-22 Press the Single user button on the remote controller Using the Single User functionEnglish-23 Using the Auto Clean function Setting the Beep soundLighting in Auto clean mode English-24Cleaning the air conditioner Cleaning the outdoor unit heat exchangerEnglish-25 Heat exchangerCleaning the air filter Removing the Air filterEnglish-26 Remove the air filter from the main bodyEnglish-27 Reassembling the Air filterTop of the Air filter into the main body.. ➀ Maintaining the air conditioner English-28Troubleshooting Air conditionerEnglish-29 Take the cover off and takeError is indicated Press the PowerOdors permeate Water is droppingEnglish-31 General information07stIn llan atio Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-33 When installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-34  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-35Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsAssembling the hanger screw English-37This QR code for detail video of indoor unit installation Removing the screwsRemoving the Cover panel Before mounting the indoor unit English-38Assembling the Cover panel After mounting the indoor unit English-39Connecting the assembly cable Cable specificationConnecting the cable English-40Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-41 English-42 Smooth the cut edgesCut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-43 Unscrew the caps at the end of each pipeCorrect Inclined English-44Cracked Drain hose installation English-45Change the direction only when it is necessary English-46Shield Downwards as seen in the pictureEvacuating the connected pipes English-47Connect a drain hose to the drain plug Drain hole Drain plugEnglish-48 Adding RefrigerantOuter Torque Please fill in with indelible ink English-491975 Performing the gas leak tests English-50Fixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-51 Smart Install mode English-52English-53 Off / Blinking / OnFinal check and trial operation English-54Packing and unpacking guide English-55How to connect your extended power cables English-56Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-57 Questions or COMMENTS? 0211