Samsung AR24HSFSEWKNMG manual Technical Specifications, 16.0 kg, 55.2 kg

Page 31

Technical Specifications

Cleaning and Maintenance

MODEL

AR18HVFSEWK/MG

 

AR24HVFSEWK/MG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLIMATE CLASS

 

T1

 

T3

 

 

T1

 

T3

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY

COOLING

18000 Btu/h

 

14500 Btu/h

24000 Btu/h

 

21200 Btu/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

-

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED VOLTAGE & FREQUENCY

 

 

230 V~60 Hz

 

 

 

230 V~60 Hz

 

RATED

COOLING

6.6 A

 

7.8 A

 

8.5 A

 

10.7 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CURRENT

HEATING (H1)

 

-

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED POWER

COOLING

1520 W

 

1700 W

1980 W

 

2430 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

HEATING (H1)

 

-

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER / COP

COOLING

11.85 (Btu/hr)/W

 

8.55 (Btu/hr)/W

12.10 (Btu/hr)/W

 

8.70 (Btu/hr)/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

-

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT

TYPE

 

 

 

 

 

 

R-410A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHARGE

 

1000 g [35.27 oz]

 

 

1600 g [56.44 oz]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANNUAL ENERGY CONSUMPTION

 

 

4104 kWh/Year

 

 

 

5346 kWh/Year

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR

27 oC

 

-

 

29 oC

 

-

27 oC

 

-

 

29 oC

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

19 oC

 

-

 

19 oC

 

-

19 oC

 

-

 

19 oC

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

35 oC

 

-

 

46 oC

 

-

35 oC

 

-

 

46 oC

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 oC

 

-

 

24 oC

 

-

24 oC

 

-

 

24 oC

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET WEIGHT

INDOOR

 

 

14.9 kg

 

 

 

16.0 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

41.7 kg

 

 

 

55.2 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS

INDOOR

1065 x 301 x 294 mm

 

1065 x 301 x 294 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OF THE UNIT

OUTDOOR

880 x 648 x 310 mm

 

880 x 793 x 310 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COUNTRY OF ORIGIN

 

 

 

 

 

THAILAND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30English

DB68-06043A-00.indd 30

4/1/2016 5:44:24 PM

Image 31
Contents Samsung Air conditionergioner Contents Safety Information on Installation Preparation InstallationFor Installation Safety InformationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning 2016 54325 PM Display Indoor Unit OverviewInserting batteries Remote Control OverviewTo 24 C Remote Control OperationControlling temperature Operation modesControlling air flow direction Controlling fan speedCooling Operation Cool modeStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeAuto mode Quick Smart FeaturesFan mode Fast function Quiet function Comfort functionBeep sound function Single user function Energy-Saving OperationTimed on/Timed off function Good’sleep function Running Auto clean Cleaning at a GlanceCleaning the filter Troubleshooting Cleaning and Maintenance 55.2 kg Technical Specifications11.85 Btu/hr/W 55 Btu/hr/W 12.10 Btu/hr/W 70 Btu/hr/W 16.0 kg15 ˚C 12.00 Btu/hr/W 75 Btu/hr/W 11.95 Btu/hr/W 65 Btu/hr/W95 W/W 20 ˚CInstallation Safety Information on InstallationPower supply line, fuse, or circuit breaker Minimum clearances for the outdoor unit Choosing the installation locationOverview of installation location requirements PreparationIndoor unit Packing and UnpackingOutdoor unit Accessories Checking and preparing accessories and toolsTools Drilling a hole through the wallTaping the pipes, cables, and drain hose Disassembling the installation plate Indoor Unit InstallationDisassembling the cover panel Connecting the power and communication cables assembly cable Prepare a compressor and the following tools Optional Extending the power cableOptional Extending the drain hose Installing and connecting the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame Panel 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board 12 Assembling the coverFixing the outdoor unit in place Outdoor Unit InstallationOptional Fixing the outdoor unit to a wall with a rack Evacuating the air Adding refrigerant Running the Smart Install mode Installation InspectionPerforming the gas leak tests LED Pumping down refrigerant Performing final check and trial operationPumping down for removing the product