Samsung AR24HSFSEWKNMG manual Packing and Unpacking, Indoor unit, Outdoor unit

Page 36

When installing more than 1 outdoor unit

(5 cases)

(Unit: mm)

1500

600

3000

3000

200

 

 

 

 

300

 

600

 

600

1500

 

 

 

 

1500

 

 

 

 

300

300

600

600

600

 

 

500

300

 

 

 

 

 

 

 

500

300

 

 

 

 

 

 

CAUTION

If the outdoor unit is installed with any insufficient clearance, it may generate sound and affect the whole product.

Be sure to install the outdoor unit in a level place where its vibration does not affect the whole product.

Step 1.2 Packing and Unpacking

Indoor unit

Packing the unit as below procedure

1Put the indoor unit onto the packing case.

2Assemble cushion-both side of indoor unit. (Left and Right)

3Seal the packing case.

Unpacking the unit as below procedure

1Open the packing case.

2Take out the both side of cushion(Left and Right).

3Move the set from the packing case.

Outdoor unit

Packing the unit as below procedure

1Put the outdoor unit onto the cushion-bottom.

2Put the cushion-top onto the outdoor unit

3Put the packing case from the top of set.

4Seal the packing case.

Unpacking the unit as below procedure

1Take out the packing case from the set.

2Take out the cushion-top.

3Move the set from the cushion-bottom.

English 35

Installation

DB68-06043A-00.indd 35

4/1/2016 5:44:30 PM

Image 36
Contents Samsung Air conditionergioner Contents Installation Safety Information on Installation PreparationSafety Information For InstallationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning 2016 54325 PM Indoor Unit Overview DisplayRemote Control Overview Inserting batteriesRemote Control Operation Controlling temperatureOperation modes To 24 CControlling fan speed Controlling air flow directionCool mode Cooling OperationStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationQuick Smart Features Auto modeFan mode Fast function Comfort function Quiet functionBeep sound function Energy-Saving Operation Single user functionTimed on/Timed off function Good’sleep function Cleaning at a Glance Running Auto cleanCleaning the filter Troubleshooting Cleaning and Maintenance Technical Specifications 11.85 Btu/hr/W 55 Btu/hr/W 12.10 Btu/hr/W 70 Btu/hr/W16.0 kg 55.2 kg12.00 Btu/hr/W 75 Btu/hr/W 11.95 Btu/hr/W 65 Btu/hr/W 95 W/W20 ˚C 15 ˚CSafety Information on Installation InstallationPower supply line, fuse, or circuit breaker Choosing the installation location Overview of installation location requirementsPreparation Minimum clearances for the outdoor unitPacking and Unpacking Indoor unitOutdoor unit Checking and preparing accessories and tools AccessoriesDrilling a hole through the wall ToolsTaping the pipes, cables, and drain hose Indoor Unit Installation Disassembling the installation plateDisassembling the cover panel Connecting the power and communication cables assembly cable Optional Extending the power cable Prepare a compressor and the following toolsInstalling and connecting the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe 10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum board12 Assembling the cover PanelOutdoor Unit Installation Fixing the outdoor unit in placeOptional Fixing the outdoor unit to a wall with a rack Evacuating the air Adding refrigerant Installation Inspection Running the Smart Install modePerforming the gas leak tests LED Performing final check and trial operation Pumping down refrigerantPumping down for removing the product