Samsung AR24HSFSEWKNMG manual 12.00 Btu/hr/W 75 Btu/hr/W 11.95 Btu/hr/W 65 Btu/hr/W, 95 W/W, 20 ˚C

Page 32

Technical Specifications

MODEL

AR18HSFSEWK/MG

AR24HSFSEWK/MG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLIMATE CLASS

 

T1

T3

 

 

T1

T3

 

 

 

 

 

 

 

 

 

 

 

CAPACITY

COOLING

18000 Btu/h

14500 Btu/h

22000 Btu/h

18000 Btu/h

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

6000 W

 

 

 

7900 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED VOLTAGE & FREQUENCY

 

 

230 V~60 Hz

 

 

 

230 V~60 Hz

 

RATED

COOLING

6.6 A

7.4 A

8.5 A

9.5 A

 

 

 

 

 

 

 

 

 

 

 

 

 

CURRENT

HEATING (H1)

 

 

6.8 A

 

 

 

10.2 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED POWER

COOLING

1500 W

1660 W

1840 W

2080 W

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

HEATING (H1)

 

 

1520 W

 

 

 

2260 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER / COP

COOLING

12.00 (Btu/hr)/W

8.75 (Btu/hr)/W

11.95 (Btu/hr)/W

8.65 (Btu/hr)/W

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

3.95 W/W

 

 

 

3.50 W/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT

TYPE

 

 

 

 

 

R-410A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHARGE

 

1500 g [52.91 oz]

 

 

2300 g [81.13 oz]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANNUAL ENERGY CONSUMPTION

 

 

4050 kWh/Year

 

 

 

4968 kWh/Year

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR

27 oC

 

20 ˚C

29 oC

 

20 ˚C

27 oC

 

20 ˚C

29 oC

 

20 ˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

19 oC

 

15 ˚C

19 oC

 

15 ˚C

19 oC

 

15 ˚C

19 oC

 

15 ˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

35 oC

 

7 ˚C

46 oC

 

7 ˚C

35 oC

 

7 ˚C

46 oC

 

7 ˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 oC

 

6 ˚C

24 oC

 

6 ˚C

24 oC

 

6 ˚C

24 oC

 

6 ˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET WEIGHT

INDOOR

 

 

15.5 kg

 

 

 

14.0 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

52.5 kg

 

 

 

71.5 kg

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS

INDOOR

1065 x 301 x 294 mm

1065 x 301 x 294 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

OF THE UNIT

OUTDOOR

880 x 793 x 310 mm

880 x 967 x 320 mm

 

 

 

 

 

 

 

 

 

 

 

COUNTRY OF ORIGIN

 

 

THAILAND

 

 

 

CHINA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cleaning and Maintenance

English 31

DB68-06043A-00.indd 31

4/1/2016 5:44:25 PM

Image 32
Contents Samsung Air conditionergioner Contents Installation Safety Information on Installation PreparationSafety Information For InstallationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning 2016 54325 PM Indoor Unit Overview DisplayRemote Control Overview Inserting batteriesRemote Control Operation Controlling temperatureOperation modes To 24 CControlling fan speed Controlling air flow directionStep cooling function Cool modeCooling Operation Dry mode Dehumidifying OperationHeat mode Heating OperationFan mode Quick Smart FeaturesAuto mode Fast function Comfort function Quiet functionBeep sound function Energy-Saving Operation Single user functionTimed on/Timed off function Good’sleep function Cleaning at a Glance Running Auto cleanCleaning the filter Troubleshooting Cleaning and Maintenance Technical Specifications 11.85 Btu/hr/W 55 Btu/hr/W 12.10 Btu/hr/W 70 Btu/hr/W16.0 kg 55.2 kg12.00 Btu/hr/W 75 Btu/hr/W 11.95 Btu/hr/W 65 Btu/hr/W 95 W/W20 ˚C 15 ˚CSafety Information on Installation InstallationPower supply line, fuse, or circuit breaker Choosing the installation location Overview of installation location requirementsPreparation Minimum clearances for the outdoor unitOutdoor unit Packing and UnpackingIndoor unit Checking and preparing accessories and tools AccessoriesDrilling a hole through the wall ToolsTaping the pipes, cables, and drain hose Disassembling the cover panel Indoor Unit InstallationDisassembling the installation plate Connecting the power and communication cables assembly cable Optional Extending the power cable Prepare a compressor and the following toolsInstalling and connecting the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a window frame 10 Fixing the installation plateWhen fixing the indoor unit on a wall 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum board12 Assembling the cover PanelOptional Fixing the outdoor unit to a wall with a rack Outdoor Unit InstallationFixing the outdoor unit in place Evacuating the air Adding refrigerant Performing the gas leak tests Installation InspectionRunning the Smart Install mode LED Pumping down for removing the product Performing final check and trial operationPumping down refrigerant