Desa 000 Btu/Hr), 44 kW (150 Nozzle, Removing Air and Fuel Line Hoses, 8,8 kW 30,000 Btu/Hr Model

Page 15

Nozzle

(8,8 kW [30,000 Btu/Hr] Model)

1.Remove upper shell (see page 10).

2.Remove fan (see page 19).

3.Remove fuel and air line hoses from nozzle assem- bly.

4.Turn nozzle assembly 1/4 turn to left and pull toward motor to remove.

5.Place plastic hex-body into vise and lightly tighten.

6.Carefully remove nozzle from the nozzle adapter using 5/8" socket wrench.

7.Blow compressed air thru face of nozzle. This will free any dirt in nozzle area.

8.Inspect nozzle seal for damage.

9.Replace nozzle into nozzle adapter until nozzle seats. Tighten 1/3 turn more using 5/8" socket wrench (40-45 inch-pounds/4.5- 5.1 n-m).

10.Attach nozzle assembly to burner strap.

11.Attach fuel and airline hoses to nozzle assembly.

12.Replace fan (see page 19).

13.Replace fan guard and upper shell.

Combustion

Chamber

Nozzle

Assembly

Fuel Line Hose

Air Line Hose

Figure 24 - Removing Air and Fuel Line Hoses, 8,8 kW (30,000 Btu/Hr) Model

Burner

Strap

Nozzle

Assembly

Figure 25 - Removing Nozzle Assembly, 8,8 kW (30,000 Btu/Hr) Model

Nozzle

Nozzle

Face

Seal

Nozzle

Nozzle

Adapter

Air line

Fuel line

Fitting

Fitting

Figure 26 - Nozzle and Nozzle Adapter, 8,8 kW (30,000 Btu/Hr) Model

15

099623

Image 15
Contents Portable Forced AIR Heaters Contents Carbon monoxide poisoning may lead to death Safety InformationProduct Identification Tools Needed Unpacking AssemblyOperation TheoryTo Start Heater Ventilation OperationTo Restart Heater Preventative Maintenance ScheduleOperation Storing To Stop HeaterHow Often How To TROUBLE- ShootingService Procedures Upper Shell RemovalFuel Filter Remove side cover screws using 5/16 nut-driver Spark Plug Removal, 8,8 kW 30,000 Btu/Hr Model Spark PlugSpark Plug Gap, 20,5/26,4/44 kW 70/90/150,000 Btu/Hr Models Air Output, Air Intake, and Lint Filters Pump Pressure AdjustmentRemoving Air and Fuel Line Hoses, 8,8 kW 30,000 Btu/Hr Model NozzleRemove upper shell see Removing Burner Head, 44 kW 150,000 Btu/Hr Model Remove rotor, insert, Pump RotorFan SpecificationsWiring Diagram, 8,8 kW 30,000 Btu/Hr Model Wiring DiagramsNumber Description QTY Illustrated Parts Breakdown and Parts ListKW 30,000 Btu/Hr Parts BreakdownKEY Part Number Description QTY Parts List20,5 kW 70,000 Btu/Hr Burner Head AssemblyFHPF3-2C 26,4 kW 90,000 Btu/Hr 098511-66 Upper Shell Black M16841-59 44 kW 150,000 Btu/Hr Illustrated Parts BreakdownNPC-4C Accessories 099623 Certificate of General Equipment Limited 90 DAY Warranty Warranty and Repair ServiceCalentadores Portatiles DE Aire Forzado Seccion Pagina ContenidoAdvertencias Informacion DE SeguridadIdentificacion DEL Producto Desembalaje Armado Combustibles Teoria DEFuncionamiento VentilacionPara apagar el calentador Para volver a encender el calentadorProcedimiento Advertencia ¡Alto voltaje Intervalo ProcedimientoFiltro de combustible Remoció n del casco superiorFiltro de combustible, buje Línea de combustible Inferior Bujía Quite el casco superior vea la Ajuste de la presió n de la bomba Filtros de salida de aire, de admisió n de aire y de pelusaBoquilla Tible del quemador Afloje la tuerca abocinada Figura Rotor de la bombaVentilador EspecificacionesAmarillo Rojo Diagramas DE AlambradoClave NO. Pieza Descripcion Despiece Ilustrado Y Lista DE PiezasKW 30,000 Btu/hr Despiece IlustradoLista DE Piezas 20,5 kW 70,000 Btu/hr Lista DE Piezas 26,4 kW 90,000 Btu/hr 098511-66 Casco superior negro 44 kW 150,000 Btu/hr M50104-03 Buje corto M10809-1 Juego DE Ruedas Y ASA DE Servicio Severo HA1202 AccesoriosNota Servicio DE Garantia Garantia Y Reparaciones