Installing the SAN Switch 2/8

Four Switch Limitation CLI Error Messages

If the fabric detects that the four switch limitation has been exceeded, the following message occurs every thirty seconds, via the Command Line Interface (CLI), as follows:

CRITICAL FABRIC-SIZE_EXCEEDED, 1, Critical fabric size <8> exceeds supported configuration <4>. Switch status marginal. Contact Technical Support.

WebTools will be disabled in 39 days 8 hours and 46 minutes.

The switch warning messages may be stored in the Syslog. Third party application SNMP traps may be configured on the switch.

Four Switch Limitation Web Tools Error Messages

If the fabric detects that the number of switches installed exceeds the four switch limit, Web Tools displays a warning message every 75 seconds (not configurable). Figure 3 shows a typical Web Tools Warning Message.

Figure 3: Four switch limitation Web Tools error message

Note: The SAN Switch 2/8 EL displays a separate error condition warning message in the dialog box.

hp StorageWorks SAN Switch 2/8 Installation Guide

25

Page 25
Image 25
HP AA-RSB6B-TE manual Four Switch Limitation CLI Error Messages