Installing the SAN Switch 2/8

1

2

 

SHR-2560A

1 Outer rail alignment pins

2 M5 torx screws

Figure 11: Assembling the outer rails

5.Assemble each of the two inner rails (one on each side of the switch and plenum) using eight #8-32 x 5/16 Phillips pan-head screws (with attached star lock washers) and eight #8 flat washers as shown in Figure 12.

Caution: Do not use any other screws other than the eight that are provided. Use of any longer lengths can cause damage to internal components of the switch. Be sure to install the flat washers along with the pan-head screws. Before tightening screws, make sure that the rails are centered to the overall height of the switch.

42

hp StorageWorks SAN Switch 2/8 Installation Guide

Page 42
Image 42
HP AA-RSB6B-TE manual Assembling the outer rails