Installing the SAN Switch 2/8
Installing the SAN Switch 2/8 in a 9000 Series or Comparable EIA Rack
Read the following sections for complete installation instructions.
Obtain the following tools:
■Fixed Rack Mount Kit (supplied with the switch)
■A #2 Phillips screwdriver with torque capability
■Clamps or other means to temporarily support the switch
■Torque screwdriver
Caution: The SAN Switch 2/8 ships with the complete set of rack mount hardware required for installation in an EIA rack. HP recommends using the exact screws specified for use with the switch chassis. Using screws longer than the specified length may damage the switch.
Installing the Fixed Rail Kit
The SAN Switch 2/8 Fixed Rack Mount Kit consists of two rail assemblies. Read the following sections for complete instructions on attaching the rails to the switch, then installing the switch in the rack.
1.Attach the left and right front brackets to the switch chassis as follows:
a.Position one left front bracket (Item 1) with the flat side against right side of switch, oriented as shown in Figure 6.
Note: Four sets of holes are provided to allow the switch to be set back from the front of the rack, if desired. This allows a more gradual bend in any fiber optic cables connected to the switch.
b.Insert two
c.Insert one
d.Tighten screws to a torque of
hp StorageWorks SAN Switch 2/8 Installation Guide | 33 |