Operating the Control Panel

Power

Use the Power button to turn the portable air conditioner on and off.

 

 

 

By default when you first use the power button, the unit will begin to

 

 

 

operate in cooling mode. The unit will remember the last used

 

 

 

mode/settings if you shut down and restart.

 

 

 

Auto-Restart:If power to the unit is interrupted, the air conditioner

 

 

 

will restart itself in its last used mode/settings once power is

 

 

 

restored. The compressor will restart after 3 minutes.

 

 

 

 

 

 

Cooling Mode

Cooling mode cools and dehumidifies the air. If the ambient

 

 

 

temperature drops below the temperature you selected, the

 

 

 

compressor turns off and the unit functions with the fan only. When

 

 

 

the temperature rises above the temperature you selected, the

 

 

 

compressor turns on again.

 

 

 

Whether your desired temperature can actually be reached

 

 

 

depends on the ambient conditions. The room temperature

 

 

 

remaining above the set temperature is normal.

 

 

 

To operate the unit in cooling mode:

 

 

 

1) Make sure the power cord is plugged into a power outlet.

 

 

 

2) Press the Power button.

 

 

NOTE: The exhaust hose

3) Press the Mode button until the LED indicator next to “Cooling”

 

 

lights up.

 

 

must be used in Cooling

 

 

4) Select the fan speed by using the Speed button.

 

 

mode in order to cool a

 

 

5) Set the thermostat by using the Up and Down buttons. The

 

 

room.

 

 

thermostat is adjustable between 61°F - 89°F in one degree

 

 

 

 

 

 

 

 

 

increments in cooling mode.

 

 

 

 

 

Dehumidifying Mode

During the Dehumidifying mode, the unit will condense water out of

the air and exhaust it through the exhaust hose. The ambient

 

 

 

 

 

 

temperature in the room will probably drop by a few degrees while

 

 

 

using the Dehumidifying mode.

To operate the unit in dehumidifying mode:

1)Make sure the power cord is plugged into a power outlet.

2)Press the Power button.

3)Press the Mode button until the LED indicator next to “Dehumidify” lights up.

NOTES: If the room temperature is below 77ºF, the fan will always run on low speed while in the Dehumidifying mode. If you do not use the exhaust hose in Dehumidifying mode, you must manually drain the water from the unit. Additionally, the ambient temperature in the room will probably rise by a few degrees if you do not use the exhaust hose. You will be not be able to change the thermostat temperature while in Dehumidifying Mode.

11

Image 14
Contents AP12000S-1 Important Safety Information Electrical SafetyTable of Contents Introduction For Your RecordsBack View Pre-filter Parts IdentificationFront View Control Panel Installing the Carbon Filter Window Kit Installation Instructions Preparations for installing the window kitInstalling the grated adapter Installing the window plates Attaching the duct connectors to the exhaust hose Connecting the duct connector to the unit Connecting the duct connector to the grated adapterDraining the Unit Direct drainageButton IndicatorControl Panel Overview FunctionDehumidifying Mode PowerCooling Mode Operating the Control PanelLCD Display Fan Only ModeSpeed Timer Water LightTimer Button Buttons Function Using the Remote ControlPower Button Mode Button Energy Saving Guide Cleaning the pre-filter MaintenanceCleaning the unit Preparation for StorageTroubleshooting Issue Possible Cause SolutionTroubleshooting Issue Possible Cause SolutionSpecifications EdgeStar Limited Warranty One 1 Year Parts & Ninety 90 Days Labor