Heatiator ADI60S owner manual Log Set Assembly LOGS-ADI60, Positioning the Logs

Page 22

F. Positioning the Logs

Log Set Assembly: LOGS-ADI60

 

 

If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the following instructions.

CAUTION: Logs are fragile! Carefully remove the logs from the packaging.

 

 

1

 

4

6

5

7

 

2

 

3

 

 

 

 

 

 

 

PILOT

BURNER

BASE PAN

1

1

LOG #1 (SRV340-701):Place log #1 in the back on the insert. Locate the legs of the log outside the 3/8” tabs to either side of the burner. Pull the log forward until the log is stopped by the back edge of the burner. The log should be centered.

2

2

LOG #2 (SRV340-702):Position log #2 by locating its slot over the tab on the front left of the burner. The slot in the left end of the log slides into the vertical metal edge in front of the square cut out on the base pan.

22

Heatilator • ADI60S • 345-900 Rev. G • 9/08

345-935 6/02

Image 22
Contents What to do if you smell gas ModelHOT Surfaces Homeowner Reference Information XxxxxxxxTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsMinimum Fireplace Opening Fireplace Size RequirementsADI60 Clearances Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesHorizontal Venting Vent Information and DiagramsVent Table Key Measuring StandardsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVenting Components Placing, Securing and Leveling the Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapFactory Built Wood Burning Class a PipeFuel Conversions Gas Connection Gas InformationGas Pressures High Altitude Installations Check for GAS LeaksElectrical Information Wiring the ApplianceON/OFF Switch Appliance RequirementsJunction Box Installation Optional AccessoriesFAN Junction BOX Finishing Mantel ProjectionsAccessories Appliance SetupClean the Appliance Ember PlacementQVI30, QVI35, ADI60 Refractory PlacementModels Supreme-XT, Grand-XT Refractory from the packagingLog Set Assembly LOGS-ADI60 Positioning the LogsAreas for LOG #4 Placement Heatilator ADI60S 345-900 Rev. G 9/08 Removing Glass Assembly Glass AssemblyAir Shutter Setting Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceWhat to do if YOU Smell GAS Check Pilot Flame Appearance Initial Break-in ProcedureAfter Appliance is Lit Frequently Asked Questions Issue SolutionsSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionMaintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsAppliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsService Parts Log Set AssemblyPart number list on following Service Parts At DepotStanding Pilot Valve Assembly StockedCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information