Heath Zenith 2LBL3, 2LBL4 operating instructions Operation, Requirements, Features

Page 1

Operating Instructions & Parts Manual

2LBL3, 2LBL4

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or main- tain the product described. Protect yourself and others by observing all safety information. Failure to comply could result in personal injury and/or property damage! Save these instructions for future reference.

®

Requirements

DualBrite® Motion Sensor Light Control

Features

DualZone™ Technology.

Turns on lighting when motion is detected.

Automatically turns lighting off.

DualBrite® Timer.

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

This package includes:

Lamp Holders

 

 

Rubber Plug

 

 

Plastic Hanger

Cover Plate

Sensor

2 Wire

Light Control

Connectors

Mounting Bolt

Mounting Strap

 

The light control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

1, 5, or 20 Min

 

x

Manual

To Dawn*

 

x

Accent

3, 6 Hr, to Dawn

 

x

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put ON-TIME switch

ON-TIME

DualBrite®

on the sensor bottom

 

 

 

 

 

 

 

 

 

 

to TEST and the Dual-

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

Off 3 6 Dusk to

Brite® switch OFF.

 

 

 

 

 

 

 

 

Dawn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO

Put the ON-TIME switch in the 1, 5,

ON-TIME

 

 

 

 

 

 

or 20 minute position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

MANUAL MODE

 

 

 

 

 

 

Gasket

2 Lamps

6 Screws

(installed)

(3 sizes included)

 

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position.

1 Second OFF

then...

... back on.

HEA 009

598-1325-00

Printed in China

LPG-5597

09/07

 

Image 1
Contents Operation FeaturesRequirements Mode Switching Summary InstallationDualBrite Timer Mounting Black to White to Strap Junction box ground wire toGreen ground screw on fixture Turn on the circuit breaker and light switch Test and AdjustmentAvoid aiming the control at Troubleshooting Guide SpecificationsYear limited warranty Características FuncionamientoRequisitos Resumen de las modalidades del interruptor InstalacionLuz de Adorno DualBrite Negro a Blanco a Advertencia Desconecte la energía en el disyuntorNegro Blanco Prenda el cortacircuitos y el interruptor de luz Prueba Y AjusteEvite apuntar el control hacia Guia DE Investigacion DE Averias EspecificacionesGarantía limitada a un 1 año Caractéristiques FonctionnementExigences Minuterie DualBriteMD Résumé du mode de commutationNoir Blanc Installation de l’ampouleEssais ET Réglages Guide DE Dépannage Fiche TechniqueGarantie limitée d’un an 598-1325-00