SPECIFICATIONS
Horizontal Range. . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [varies with surrounding temperature]
Vertical Range. . . . Up to 15 ft. (4.6 m)
Sensing Angle. . . . Up to 240° horizontal. Up to 80°
Vertical
Electrical Load. . . . Up to 200 Watts Maximum In- candescent (Up to 100 Watts Maximum each lamp holder.)
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . TEST, AUTO and MANUAL
MODE
. 1, 5, 20 minutes
. Off, 3, 6 hours,
VAC
TROUBLESHOOTING GUIDE
SYMPTOM | POSSIBLE CAUSE | |
|
|
|
Lights will | 1. | Light switch is turned off. |
not come | 2. | Light is loose or burned out. |
on. | 3. | Fuse is blown or circuit breaker is turned |
|
| off. |
| 4. | Daylight turnoff is in effect (recheck after |
|
| dark). |
| 5. | Incorrect circuit wiring, if this is a new |
|
| installation. |
| 6. | |
|
|
|
Lights come | 1. | Light control may be installed in a rela- |
on in day- |
| tively dark location. |
light. | 2. | Light control is inTest.(Set control switch |
|
| to an |
|
|
|
Lights come | 1. | Light control may be sensing small |
on for no |
| animals or automobile traffic |
apparent |
| sensor). |
reason. | 2. | Range is set too high. (Reduce Range |
|
| setting). |
| 3. | DualBrite® Timer is on. |
Lights turn | 1. | Sensor is in a relatively dark location. |
off too late |
| (Relocate sensor, or use 3 hr or 6 hr |
in Dusk- |
| setting). |
|
| |
setting. |
|
|
|
|
|
SYMPTOM | POSSIBLE CAUSE | |
|
|
|
Lights stay | 1. | A lamp is positioned too close to the |
on continu- |
| sensor or pointed at nearby objects |
ously. |
| that cause heat to trigger the sensor. |
|
| (Reposition the lamp away from the |
|
| sensor or nearby objects). |
| 2. | Light control is pointed toward a heat |
|
| source like an air vent, dryer vent, or |
|
| |
|
| (Reposition sensor. Reduce Range). |
| 3. | Light control is in Manual Mode. (Switch |
|
| to Auto). |
|
|
|
Lights flash | 1. | Heat or light from the lamps may be |
on and off. |
| turning the light control on and off. |
|
| (Reposition the lamps away from the |
|
| sensor). |
| 2. | Heat being reflected from other objects |
|
| may be affecting the sensor. (Reposi- |
|
| tion sensor). |
| 3. | Light control is in the Test mode and |
|
| warming up.(Flashing is normal under |
|
| these conditions. Turn Boost off). |
|
|
|
Lights flash | 1. | Sensor is detecting its own lights. |
once, then |
| (Reposition lamps to keep area below |
stay off in |
| the sensor relatively dark). |
Manual Mode. |
|
|
|
|
|
1 Year limited warranty:
Should this product fail to perform satisfactorily due to a defect or poor workmanship within one year of date of purchase, return it to the place of purchase and it will be replaced, free of charge. Incidental or consequential damages are excluded from this warranty. Light bulbs are not covered.
Manufactured for Grainger International, Inc.
Lake Forest, IL 60045