OPERATING HEATER (THERMOSTATICALLY-CONTROLLED MODELS)

Lighting Instructions

19

OPERATING HEATER

Continued

LIGHTING INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fire- place will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burn- ing logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information in column 2, page 18.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information in column 2, page 18. If you don’t smell gas, go to the next step.

5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Fig- ure 40).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure. page 20.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise C-clockwiseto desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

 

HI

L

OFF

O

Pilot

Ignitor Button

Control Knob

Figure 40 - Control Knob and Ignitor Button Location

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 41 - Pilot

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

For morevisit www..com

107123-01E

Image 19
Contents What to do if YOU Smell GAS OWNER’S Operation Installation ManualUnvented VENT-FREE Natural GAS LOG Heaters Biltmore Split OAK, Seasonal OAK, Smoky Mountain OAK LogsSafety Information Table of ContentsProduct Identification AIR for Combustion and Ventilation Product FeaturesUnpacking Local CodesConfined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Minimum Firebox Size Log Front Rear Height Depth Width InstallationInstallation Check GAS TypeMinimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesArea of Various Standard Round Flues Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping systemPressure Testing Heater Gas Connections Installing LogsDual Burner Smoky Mountain Oak Models Dual Burner Biltmore Split Oak Models Dual Burner Premium Aged Split Oak ModelsInstalling Rear Log Single Burner Seasonal Oak Models Installing Crossover LogOperating Heater For Your Safety Read Before LightingLighting Instructions Shutting Off Heater Manual Lighting ProcedureVariable Control Operation To Turn OFF GAS to ApplianceIgnitor Button Inspecting Burners Cleaning and MaintenanceModel SpecificationsLogs Model ModelsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at top TopFor Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbBreakdown Illustrated PartsDescription QTY Parts ListCGD3018NT CGD3924NT CGD3930NT Illustrated Parts BreakdownCGD3018NT CGD3924NT CGD3930NT Thermostatically-Controlled Biltmore Split Oak Model CCL3018NTCCL3018NT CCL3924NT, CCL3930NTA CCL3924NT CCL3930NTA Variable Manually-Controlled Seasonal Oak Models CRL2718N CRL3124N Variable Manually-Controlled Mountain Oak ModelsAccessories Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required Parts Central Warranty Information